SCIENTIFIC REPORT The effects of corneal parameters on the assessment of endothelial cell density in the elderly eye

نویسندگان

  • A Müller
  • J P Craig
  • C N Grupcheva
  • C N J McGhee
چکیده

Background: The possible impact of corneal thickness, curvature, and size on the measurement of endothelial cell density (ECD) has largely been ignored in the normal eye. The aim of this study was to investigate the possible impact of the main corneal parameters on the analysis of ECD values at the central, superior, and temporal parts of the corneal surface. Methods: All 75 participants (52 females, 23 males) were assessed as part of a pre-cataract surgery investigation. The mean age was 75.7 (SD 10.9) years. Confocal microscopy was used to measure ECD and the percentage of six sided cells at the central, superior, and temporal parts of the cornea. The Orbscan II topography system was used to measure corneal thickness, topography, and horizontal corneal diameter. Results: The mean central ECD measured was 2488 (SD 301) cells/mm, compared with 2525 (SD 505) cells/mm in the temporal cornea and 2639 (SD 398) cells/mm in the superior cornea. The regional differences in ECD were not significant (p.0.14). The central ECD was significantly correlated to the central (mean 0.593 (SD 0.039) mm, p = 0.021) as well as the temporal (0.628 (SD 0.039) mm, p,0.001) and the superior corneal thickness (SD 0.644 (SD 0.048) mm, p = 0.018). The mean corneal curvature at the centre (7.7 (SD 0.34) mm, p = 0.002) as well as 3 and 5 mm from the apex was significantly related to ECD (p = 0.008 and p = 0.009, respectively). Conclusions: The study suggests that in an older population, lower ECD values would be expected in thinner and/or steeper corneas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی سلول‌های اندوتلیوم قرنیه در افراد مبتلا به قوز قرنیه و سالم

Background: In this study were focused on corneal cells changes in keratoconus disease, as there are differences between results of other studies that were done on keratokonic eyes. And the chief purpose was a comparison between keratoconus and normal population based corneal endothelium (in cell density, pleomorphism and polymegethism of cells). Methods: This study is an observational study a...

متن کامل

Frequency of Causes of Corneal Re-graft during 5 Years at Khalili Hospital, Shiraz

Purpose: To evaluate study of corneal the frequency of re-graft during 5 years at Khalili hospital, Shiraz. Methods: In this retrospective observational study, all corneal re-grafts during 5 years (2009-2014) were assessed at Khalili Hospital, Shiraz. Demographic data of 76 cases, out of total of 1 190 transplants, were retrieved, including age, area of residence, primary disease, type of graft...

متن کامل

Effect of Fas -670 A/G Gene Polymorphism on Corneal Allograft Endothelial Rejection

Background: Human cornea expresses functional Fas-ligand capable of killing Fas+ activated lymphocytes. Fas expression is partly regulated by -670 A/G polymorphism in the promoter region of Fas gene. Objective: The aim of the present study is to determine the association between Fas-670A/G polymorphism and survival of corneal transplantation. Methods: In 276 graft recipients who mainly underwen...

متن کامل

A 3-decade Activity of the Central Eye Bank of Iran

Purpose: To report a 3-decade eye bank data and activity of the Central Eye Bank of Iran (CEBI). Methods: All the eye bank records in terms of procured eyes, utilized tissues, corneal transplants per capita, and indications for keratoplasty over the last 3 decades were analyzed. Results: During the last 27 years, 115 743 whole eyes were donated, among which 114 169 eyes were donated between 199...

متن کامل

Cigarette Smoking and Pachymetry and Specular Microscopy Parameters of Cornea; A Systematic Review and Meta-analysis

Purpose: To investigate the effect of smoking on corneal parameters, including Endothelial Cell Density, Central Corneal Thickness, Percent of Hexogonality, and Coefficient of Variation. Methods: This study was a systematic review and meta-analysis of published articles until the end of February 2019. To do this, the first search was done for creditable medical databases such as PubMed, and ISI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004