Analysis of fast dynamic processes in living cells: high-resolution and high-speed dual-color imaging combined with automated image analysis.
نویسندگان
چکیده
The generation of spectral mutants of the green fluorescent protein (GFP) set the stage for multiple-color imaging in living cells. However, the use of this technique has been limited by a spectral overlap of the available GFP mutants and/or by insufficient resolution in both time and space. Using a new setup for dual-color imaging, we demonstrate here the visualization of small, fast moving vesicular structures with a high time resolution. Two GFP-fusion proteins were generated: human chromogranin B, a secretory granule matrix protein, and phogrin, a secretory granule membrane protein. They were tagged with enhanced yellow fluorescent protein (EYFP) and enhanced cyan fluorescent protein (ECFP), respectively. Both fusion proteins were cotransfected in Vero cells, a cell line from green monkey kidney. EYFP and ECFP were excited sequentially at high time rates using a monochromator. Charged coupled device (CCD)-based image acquisition resulted in 5-8 dual-color images per second, with a resolution sufficient to detect transport vesicles in mammalian cells. Under these conditions, a fully automated time-resolved analysis of the movement of color-coded objects was achieved. The development of specialized software permitted the analysis of the extent of colocalization between the two differentially labeled sets of cellular structures over time. This technical advance will provide an important tool to study the dynamic interactions of subcellular structures in living cells.
منابع مشابه
I-1: Screening of Subfertile Men for Testicularlar Carcinoma In Situ by An Automated Image Analysis-Based Cytological Test of The Ejaculate
Background: Testicular cancer (TC) is usually diagnosed after manifestation of an overt tumour. Tumour formation is preceded by a pre-invasive and asymptomatic stage, carcinoma in situ (CIS) testis, except for very rare subtypes. The CIS cells are located within seminiferous tubules but can be exfoliated and detected in ejaculates with specific CIS markers. Materials and Methods: We have built ...
متن کاملImage Retrieval Using Dynamic Weighting of Compressed High Level Features Framework with LER Matrix
In this article, a fabulous method for database retrieval is proposed. The multi-resolution modified wavelet transform for each of image is computed and the standard deviation and average are utilized as the textural features. Then, the proposed modified bit-based color histogram and edge detectors were utilized to define the high level features. A feedback-based dynamic weighting of shap...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملControl Issues in High-speed AFM for Biological Applications: Collagen Imaging Example.
This article considers the precision positioning problem associated with high-speed operation of the Atomic Force Microscope (AFM), and presents an inversion-based control approach to achieve precision positioning. Although AFMs have high (nanoscale) spatial resolution, a problem with current AFM systems is that they have low temporal resolution, i.e., AFM imaging is slow. In particular, curren...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioTechniques
دوره 28 4 شماره
صفحات -
تاریخ انتشار 2000