P 453 Measurement of ocular deviation by photographic analysis of the corneal reflex. Results in 15 normal subjects
نویسندگان
چکیده
Purpose : A new method of calibration of the displacement of the cornea1 reflex in relation to the angular deviation was carried out on a population of normal subjects. Methods : The position of the cornea1 reflex was studied in 15 normal adult subjects, emmetropic and orthophoric. Each eye, photographed individually, was situated perpendicularly at the zero of a tangential scale. Slides taken in 17 positions of gaze permitted measurement of the distance of the cornea1 reflex from the nasal and temporal limbus. Calculation of the displacement of the reflex in relation to the primary position was expressed as percentage deviation of the reflex. Results : The regressions made between the angular deviation expressed in dioptres and the percentage deviation of the reflex demonstrated the existence of a linear relation. Perfect correspondence was found to exist between the right and left eyesThe calculation as a percentage, taking the cornea1 diameter into account, allowed errors in extreme positions of gaze to be minimized. Direct measurement in millimeters allowed us to find a conversion factor of 21,6 A of angular deviation per millimeter deviation of the reflex. COI’IC~UB~OIIB : The statistical results found in this study confirmed the close correlation between the position of the cornea1 reflex and the ocular deviation. One millimeter of cornea1 reflex deviation corresponds to an angular rotation of 21,6 A. COMPARATIVE STUDY OF THE ERG ONAND OFF-RESPONSE SPECTRAL SENSITIVITY: INFLUENCE OF GABAERGIC SYSTEM. KUPENOVA P. VITANOVA L. POPOVA E. MITOV' ' rT Y . Dept. Physiology, Medical Faculty, Sofia, Bulgaria
منابع مشابه
بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کاملP 455 Measurement of the anaesthetic test by a photographic method on a series of patients with esotropias never previously operated
Purpose : A new method of calibration of the displacement of the cornea1 reflex in relation to the angular deviation was carried out on a population of normal subjects. Methods : The position of the cornea1 reflex was studied in 15 normal adult subjects, emmetropic and orthophoric. Each eye, photographed individually, was situated perpendicularly at the zero of a tangential scale. Slides taken ...
متن کاملP 454 Comparative study of the ERG on- and off-response spectral sensitivity: Influence of GABAergic system
Purpose : A new method of calibration of the displacement of the cornea1 reflex in relation to the angular deviation was carried out on a population of normal subjects. Methods : The position of the cornea1 reflex was studied in 15 normal adult subjects, emmetropic and orthophoric. Each eye, photographed individually, was situated perpendicularly at the zero of a tangential scale. Slides taken ...
متن کاملP 452 Is keystroke usuable as an ergophtalmic tool?
Purpose : A new method of calibration of the displacement of the cornea1 reflex in relation to the angular deviation was carried out on a population of normal subjects. Methods : The position of the cornea1 reflex was studied in 15 normal adult subjects, emmetropic and orthophoric. Each eye, photographed individually, was situated perpendicularly at the zero of a tangential scale. Slides taken ...
متن کاملCervical and ocular vestibular evoked myogenic potentials in multiple sclerosis participants
Background: Multiple sclerosis (MS) is a chronic neurological disease that affects brain and spinal cord. The infratentorial region contains the cerebellum and brainstem. Vestibular evoked myogenic potentials (VEMPs) are short-latency myogenic responses. Cervical vestibular evoked myogenic potential (cVEMP) is a manifestation of vestibulocolic reflex and ocular vestibular evoked myogenic pote...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 35 شماره
صفحات -
تاریخ انتشار 1995