An in vitro lung model to assess true shunt fraction by multiple inert gas elimination

نویسندگان

  • Balamurugan Varadarajan
  • Andreas Vogt
  • Volker Hartwich
  • Rakesh Vasireddy
  • Jolanda Consiglio
  • Beate Hugi-Mayr
  • Balthasar Eberle
چکیده

The Multiple Inert Gas Elimination Technique, based on Micropore Membrane Inlet Mass Spectrometry, (MMIMS-MIGET) has been designed as a rapid and direct method to assess the full range of ventilation-to-perfusion (V/Q) ratios. MMIMS-MIGET distributions have not been assessed in an experimental setup with predefined V/Q-distributions. We aimed (I) to construct a novel in vitro lung model (IVLM) for the simulation of predefined V/Q distributions with five gas exchange compartments and (II) to correlate shunt fractions derived from MMIMS-MIGET with preset reference shunt values of the IVLM. Five hollow-fiber membrane oxygenators switched in parallel within a closed extracorporeal oxygenation circuit were ventilated with sweep gas (V) and perfused with human red cell suspension or saline (Q). Inert gas solution was infused into the perfusion circuit of the gas exchange assembly. Sweep gas flow (V) was kept constant and reference shunt fractions (IVLM-S) were established by bypassing one or more oxygenators with perfusate flow (Q). The derived shunt fractions (MM-S) were determined using MIGET by MMIMS from the retention data. Shunt derived by MMIMS-MIGET correlated well with preset reference shunt fractions. The in vitro lung model is a convenient system for the setup of predefined true shunt fractions in validation of MMIMS-MIGET.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of inhaled nitric oxide on pulmonary function after sepsis in a swine model.

BACKGROUND Inhaled nitric oxide (NO) has been shown to improve sepsis induced pulmonary dysfunction. This study evaluated the mechanism by which inhaled NO improves pulmonary function in a porcine sepsis model. METHODS After an infusion of Escherichia coli lipopolysaccharide (LPS, 200 micrograms/kg), animals were resuscitated with saline solution (1 ml/kg/min) and observed for 3 hours while m...

متن کامل

A comparison of micropore membrane inlet mass spectrometry-derived pulmonary shunt measurement with Riley shunt in a porcine model.

BACKGROUND The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model....

متن کامل

Dynamic changes in shunt and ventilation-perfusion mismatch following experimental pulmonary contusion.

The objective of this study was to investigate early changes in oxygenation by means of the multiple inert gas elimination technique and in coagulation by means of thromboelastography (TEG) after right-sided pulmonary contusion (PC) in swine. Anesthetized swine (group 1; n = 8) sustained a right-chest PC by a captive-bolt stunner. Multiple inert gas elimination technique, TEG, and thoracic comp...

متن کامل

Effects of heparin and lisofylline on pulmonary function after smoke inhalation injury in an ovine model.

OBJECTIVE This study evaluates the effects of heparin alone and in combination with lisofylline, 1-(5-R-hydroxyhexyl)3,7-dimethylxanthine, on severe smoke injury. DESIGN Prospective animal study with concurrent controls. SETTING An animal laboratory. SUBJECTS Eighteen 1-yr-old female sheep, weighing 24-32 kg. INTERVENTIONS After smoke exposure and tracheostomy, animals were divided into...

متن کامل

Reproduction of MIGET retention and excretion data using a simple mathematical model of gas exchange in lung damage caused by oleic acid infusion.

The multiple inert-gas elimination technique (MIGET) is a complex mathematical model and experimental technique for understanding pulmonary gas exchange. Simpler mathematical models have been proposed that have a limited view compared with MIGET but may be applicable for use in clinical practice. This study examined the use of a simple model of gas exchange to describe MIGET retention and excre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017