Microbubble-based scans reach beyond liver
نویسنده
چکیده
Ultrasound is the most commonly used abdominal imaging modality. The addition of color and spectral Doppler imaging has been particularly beneficial. When ultrasound findings are nonspecific, however, patients are generally referred to CT or MRI. A contrast-enhanced ultrasound examination could alleviate the need for these more expensive imaging investigations, and a number of micro-bubble-based agents exist. The predominant agent used in Europe is SonoVue (Bracco). Other available agents include Definity (Bristol-Myers Squibb) and Optison (GE Healthcare). All microbubbles are filled with gas; sulfur hexachloride in the case of SonoVue, perfluoropro-pane in the case of Definity. The gas-filled bubbles are smaller than red blood cells, so they will undergo pulmonary recirculation. When injected intravenously, the micro-bubbles remain in the blood pool for up to six minutes.1 Technological advances, particularly the advent of harmonic and pulse-inversion imaging, have contributed to improvements in microbubble-based imaging. All major manufacturers of ultrasound equipment offer add-on software packages that allow for contrast-enhanced imaging, albeit at an extra cost. Microbubble contrast agents have an excellent safety profile and can be used in patients with renal impairment.2 Many clinical radiology departments across Europe now use micro-bubble contrast agents for ultrasound scans of the liver. Published guidelines are available on the characterization of focal liver lesions using contrast-enhanced ultrasound,3,4 and good concordance with CT and MRI has been demonstrated.5 The extension of contrast-enhanced ultrasound into other abdominal structures outside of the liver is on the horizon, though the potential role for microbubble agents in these organs is not as well appreciated at present. The agents may be used to depict disease processes in the spleen, kidneys, gallbladder, bowel, and pancreas.
منابع مشابه
Assessment of track microbubble flow signals on contrast-enhanced ultrasound with perflubutane following percutaneous liver biopsy.
OBJECTIVE It is important to detect post-liver biopsy hemorrhage early and confirm hemostasis in the clinical setting. Contrast-enhanced ultrasound (CEUS) is a sensitive and highly specific tool for detecting active bleeding. The aim of this study was to investigate the rate of detection of track microbubble flow signals on CEUS with perflubutane following liver biopsy and to assess the disappe...
متن کاملA High-Sensitive Pressure Sensor Using a Single-Mode Fiber Embedded Microbubble with Thin Film Characteristics
A new fiber pressure sensor is proposed and analyzed in this paper. A commercial arc fusion splicer and pressure-assisted arc discharge technology are used here to fabricate a silica hollow microbubble from a common glass tube with the characteristics of a thin film. Then the single mode fiber is embedded into the microbubble to form a fiber Fabry-Perot interferometer by measuring the reflected...
متن کاملHigh correlation between microbubble contrast-enhanced ultrasound, magnetic resonance and histopathology in the evaluation of hepatocellular carcinoma
OBJECTIVES To evaluate the efficacy of microbubble contrast ultrasound in diagnosis of hepatocellular carcinoma and to compare its results with those of magnetic resonance and histopathology. METHODS A total of 29 patients suffering from chronic liver diseases and awaiting liver transplants at Hospital Israelita Albert Einstein were subject to magnetic resonance, microbubble contrast ultrasou...
متن کاملGas-filled microbubbles--a novel susceptibility contrast agent for brain and liver MRI.
Gas-filled microbubbles have the potential to become a unique intravascular MR contrast agent due to their magnetic susceptibility effect, biocompatibility and localized manipulation via ultrasound cavitation. However, in vivo demonstration of microbubble susceptibility effect is limited so far and microbubble susceptibility effect is relatively weak when compared with other intravascular MR su...
متن کاملHemostatic Effects of Microbubble-Enhanced Low-Intensity Ultrasound in a Liver Avulsion Injury Model
OBJECTIVES Microbubble-enhanced therapeutic ultrasound (MEUS) can block the blood flow in the organs. The aim of this study was to evaluate the hemostatic effect of microbubble-enhanced pulsed, low-intensity ultrasound in a New Zealand White rabbit model of avulsion trauma of the liver. The therapeutic ultrasound (TUS) transducer was operated with the frequency of 1.2 MHz and an acoustic pressu...
متن کامل