Collateral-flow measurements in humans by myocardial contrast echocardiography: validation of coronary pressure-derived collateral-flow assessment.

نویسندگان

  • Rolf Vogel
  • Rainer Zbinden
  • Andreas Indermühle
  • Stephan Windecker
  • Bernhard Meier
  • Christian Seiler
چکیده

AIMS Myocardial blood flow (MBF) is the gold standard to assess myocardial blood supply and, as recently shown, can be obtained by myocardial contrast echocardiography (MCE). The aims of this human study are (i) to test whether measurements of collateral-derived MBF by MCE are feasible during elective angioplasty and (ii) to validate the concept of pressure-derived collateral-flow assessment. METHODS AND RESULTS Thirty patients with stable coronary artery disease underwent MCE of the collateral-receiving territory during and after angioplasty of 37 stenoses. MCE perfusion analysis was successful in 32 cases. MBF during and after angioplasty varied between 0.060-0.876 mL min(-1) g(-1) (0.304+/-0.196 mL min(-1) g(-1)) and 0.676-1.773 mL min(-1) g(-1) (1.207+/-0.327 mL min(-1) g(-1)), respectively. Collateral-perfusion index (CPI) is defined as the rate of MBF during and after angioplasty varied between 0.05 and 0.67 (0.26+/-0.15). During angioplasty, simultaneous measurements of mean aortic pressure, coronary wedge pressure, and central venous pressure determined the pressure-derived collateral-flow index (CFI(p)), which varied between 0.04 and 0.61 (0.23+/-0.14). Linear-regression analysis demonstrated an excellent agreement between CFI(p) and CPI (y=0.88 x +0.01; r(2)=0.92; P<0.0001). CONCLUSION Collateral-derived MBF measurements by MCE during angioplasty are feasible and proved that the pressure-derived CFI exactly reflects collateral relative to normal myocardial perfusion in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative contrast echocardiographic assessment of collateral derived myocardial perfusion during elective coronary angioplasty.

OBJECTIVE To determine whether myocardial contrast echocardiography can be used to quantify collateral derived myocardial flow in humans. METHODS In 25 patients undergoing coronary angioplasty, a collateral flow index (CFI) was determined using intracoronary wedge pressure distal to the stenosis to be dilated, with simultaneous mean aortic pressure measurements. During balloon occlusion, echo...

متن کامل

Assessment of the collateral circulation of the heart.

Ever since the development of coronary angiography in the early 1960s, the collateral circulation of the heart has fascinated cardiologists and has been the subject of sometimes contradictory and speculative theories. The basis for systematic study of the collateral circulation has been provided by the seminal work of Schaper, who started to perform experimental studies as early as 40 years ago...

متن کامل

Assessment of Myocardial Collateral Blood Flow with Contrast Echocardiography

Humans have pre-formed collateral vessels that enlarge with ischemia. In addition, new vessels can be formed within ischemic zones from pre-formed endocardial arcades of vessels providing rich collateral flow. Collateral flow under resting conditions (if >25% of normal) is enough to maintain myocardial viability, but may be insufficient to prevent myocardial ischemia under stress. Coronary angi...

متن کامل

Validation of collateral fractional flow reserve by myocardial perfusion imaging.

BACKGROUND Collateral fractional flow reserve (FFR(coll)) is an index to quantify collateral blood flow, derived from coronary pressure measurements. Although well defined theoretically, its direct validation by myocardial perfusion imaging has not been established so far. Validating this index by myocardial perfusion imaging is the main aim of this study. METHODS AND RESULTS Twenty-four cons...

متن کامل

Combined assessment of reflow and collateral blood flow by myocardial contrast echocardiography after acute reperfused myocardial infarction.

OBJECTIVE To evaluate the combined assessment of reflow and collateral blood flow by myocardial contrast echocardiography after myocardial infarction. DESIGN Myocardial contrast echocardiography was performed in patients with acute myocardial infarction shortly after successful coronary reperfusion (TIMI 3 patency) by direct angioplasty. Collateral flow was assessed before coronary angioplast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 2006