Conformal prostate brachytherapy guided by realtime dynamic dose calculations using permanent 125iodine implants: technical description and preliminary experience.

نویسندگان

  • Pedro J Prada
  • German Juan
  • José Fernández
  • H González-Suárez
  • Alvaro Martínez
  • José González
  • Ana Alonso
چکیده

OBJECTIVE Low dose rate (LDR) prostate brachytherapy (permanent 125I or 103Pd seeds) is an accepted treatment option for low risk prostate cancer patients. However, differences in prostate spatial location, volume and gland deformation between the images obtained during pre-planning and later on during the implant procedure prevent the pre-planned intended dose to be accurately delivered. We are reporting on a new technique based on interactive real-time dynamic intra-operative dose calculation with avoidance of postimplant CT for final dosimetry. The reasons leading us to implementing this new technique are discussed and preliminary results reported. 47-78 years). For the real time intra-operative dosimetric analysis the following values were obtained: a median of 98% (90%-100%) for V90, of 60% (22%-76%) for V150 and 24% (9%-34%) for V200. The median intro-operative D90 obtained was 16,817 cGy with a range of 13,743 to 19,553 cGy. The median dose point calculation to the rectum maximum was 12,936 cGy and for the maximum in urethra was 21,880 cGy. For the real-time dynamic planning, the acute GU grade 1&2 toxicity was reduced from 28% and 2 1% to 16% and 6% respectively. Acute urinary retention was seen in 2/63 or 3% requiring a temporary post-implant bladder catheter. In addition, a decrease in chronic GU grade 1-2 toxicity was also seen from 16% and 17% to 1 1% and 2% respectively. No change in GI toxicity pattern was noted. No severe grade 3-4 intra-operative complications were noted. CONCLUSION Real-time intra-operative planning was successfully implemented in our center. It avoids the possible implant quality and dose delivery disadvantages of the standard post-implant CT-based dosimetry by improving the accuracy of seed placement on real time, which was translated in lower rates of acute and chronic GU morbidity. In addition, avoids the unnecessary time, effort and cost of post-implant CT-based dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal drug release schedule for in-situ radiosensitization of image guided permanent prostate implants

Planned in-situ radiosensitization may improve the therapeutic ratio of image guided I prostate brachytherapy. Spacers used in permanent implants may be manufactured from a radiosensitizer-releasing polymer to deliver protracted localized sensitization of the prostate. Such devices will have a limited drug-loading capacity, and the drug release schedule that optimizes outcome, under such a cons...

متن کامل

High-dose-rate Brachytherapy for Prostate Cancer

Introduction/Background Over the last 2 decades, significant technical advancements have improved the delivery of prostate brachytherapy. The transrectal ultrasound-guided implant technique is the backbone of modern prostate brachytherapy. Whether it is permanent or temporary, ie, low-dose-rate (LDR) or high-dose-rate (HDR), respectively, both use similar image-guided techniques for inserting s...

متن کامل

Dose escalation in permanent brachytherapy for prostate cancer: dosimetric and biological considerations.

No prospective dose escalation study for prostate brachytherapy (PB) with permanent implants has been reported. In this work, we have performed a dosimetric and biological analysis to explore the implications of dose escalation in PB using 125I and 103Pd implants. The concept of equivalent uniform dose (EUD), proposed originally for external-beam radiotherapy (EBRT), is applied to low dose rate...

متن کامل

Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer

Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...

متن کامل

The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos espanoles de urologia

دوره 59 9  شماره 

صفحات  -

تاریخ انتشار 2006