Cut-off levels based on deviation from standard negative control is better than moderate level based on fixed cut-off for ACA assessed using ELISA for the diagnosis of antiphospholipid syndrome.

نویسندگان

  • Shufrie Effendy
  • Karmel L Tambunan
  • A Harryanto Reksodiputro
چکیده

AIM To assess the consistency of the standard negative control of IgG and IgM ACA levels within runs and batches of tests, and levels of ACA agreement between those established according to deviation from standard negative control and those established based on a fixed level cut off. METHODS Serum samples of 148 patients who presented an INR < 0.9 or prothrombin activity of > 130% or aPTT below 0.8 times control or thrombosis with aPTT below 1.2 times control were tested in a 22-time running test to determine IgG and IgM ACA levels using Quanta Lite ACA IgG (HRP) and Quanta Lite ACA IgM (HRP) commercial reagents. RESULTS Coefficients of variant within runs and batches of standard negative control IgG and IgM ACA levels were 19.30% and 29.17% respectively. Using kappa statistics to determine degree of agreement between cut-off levels by deviation from standard negative control and fixed cut-off level of ACA identified using ELISA, the disagreement in IgM and IgG were k 0.30, and 95% CI of k 0.27 to 0.34 (z = 1.033, p = 0.3015), and k 0.63, and 95% CI of k 0.53 to 0.73 (z = 1.411, p = 0.1584) for cut-off levels based on deviations from standard negative control and fixed cut-off levels respectively. Cut-off levels based on deviation from standard negative control was more sensitive, with a 92% predictive true positive value, compared to a 69% predictive true positive value by fixed cut-off levels of IgM ACA detected using ELISA, and nearly equivalent to IgG ACA, with 84.4% and 87.1% predictive true positive values respectively. CONCLUSION Cut-off points based on fixed levels of ACA detected using ELISA cannot be applied, because both IgG and IgM ACA levels of standard negative control were inconsistent among runs and batches. Cut-off points based on the deviation of 3 standard negative control levels for IgG ACA and based on deviations of 2.5 times from standard negative control levels for IgM ACA were better than cut off by fixed levels of ACA in producing true positive results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

محاسبه Cut-off point مناسب برای آزمون ELISA جهت تشخیص بروسلوز انسانی در ایران

Background: Finding a reliable diagnostic method for brucellosis is the most challengeable problem. In this study we determined the optimal diagnostic cut-off point for ELISA test.Methods: We gathered 56 confirmed cases of brucellosis. Furthermore blood samples from 126 controls including 73 healthy controls and 53 without brucellosis febrile patients were collected. In all of the cases and con...

متن کامل

O-30: Evaluation of Anti-Mullerian Hormone (AMH) Cut-Off Levels in Serum and Follicular Fluid in Patients with and without Endocrinological Risk Factor in ART

Background: Assessment of AMH cut-off levels in serum and in follicle fluid (FF) for patients with (group 2, n=34) and without (group1, n= 96) endocrinological risk factors, such as ovarian hyperstimulation syndrome (OHSS) and polycystic ovary syndrome (PCOS), is clinically useful in optimising the treatment protocol. Materials and Methods: AMH was analysed in serum and FF of 130 infertile pati...

متن کامل

Diagnosis of mixed gastrointestinal nematode infection in goat by an indirect-ELISA

An indirect-ELISA for the diagnosis of mixed gastrointestinal (GI) nematode infection comprising Oesophagostomum, Haemonchus and Trichuris species was standardized using crude somatic antigen of Oesophagostomum columbianum (CSAg-Oc) and sera of slaughtered goats with known parasitological status including Oesophagostomum, Haemonchus, and <em...

متن کامل

Cut-Off Levels of Anti-Mullerian Hormone for The Prediction of Ovarian Response, In Vitro Fertilization Outcome and Ovarian Hyperstimulation Syndrome

Background Evaluation of anti-mullerian hormone (AMH) cut-off levels in assisted reproductive technology (ART) as predictive factor for individualization of stimulation protocols and to avoid ovarian hyperstimulation syndrome (OHSS). MaterialsAndMethods In a retrospective study, 177 infertile patients were assessed for AMH in serum and follicular fluid (FF) on the day of follicular puncture (FP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta medica Indonesiana

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 2005