Selectivity of intramuscular stimulating electrodes in the lower limbs.
نویسندگان
چکیده
Intramuscular (IM) electrodes have been used safely and effectively for decades to activate paralyzed muscles in neuroprosthetic systems employing functional electrical stimulation (FES). However, the response to stimulation delivered by these and any type of electrode can be limited by a phenomenon known as spillover, in which the stimulus intended to produce a contraction in a particular muscle inadvertently activates another muscle, causes adverse sensation, or triggers undesired reflexes. The purpose of this retrospective study was to determine the selectivity of monopolar intramuscular stimulating electrodes implanted in the lower limbs of individuals with motor and sensory complete paraplegia secondary to spinal cord injury (SCI) and to catalog the most common electrode spillover patterns. The performance records of 602 electrodes from 10 subjects who participated in a program of standing and walking with FES in our laboratory over the past decade were examined. Sixty percent (358) of these electrodes were "stable" (i.e., stimulated responses were consistent during the first 6 months postimplant), and 32% of all stable electrodes (113) exhibited spillover as noted in clinical and laboratory records. Common spillover patterns for eight muscle groups were tabulated and analyzed in terms of their functional implications. The beneficial (activation of synergistic muscles) or deleterious (activation of compromising reflexes, antagonists, or adverse sensation) effects of spillover were highly context dependent, with several potentially useful spillover patterns in certain phases of gait becoming undesirable and limiting in others. Knowledge of the selectivity of intramuscular electrodes and the patterns of spillover they exhibit should guide surgeons and rehabilitationists installing lower-limb neuroprostheses during the implantation process and allow them to better predict the ultimate functional usefulness of the electrodes they choose.
منابع مشابه
Perspectives on New Electrode Technology for Stimulating Peripheral Nerves with Implantable Motor Prostheses
The limits of present electrode technology are being reached in current motor prostheses for restoring functional movement in paralyzed people. Improved devices require electrodes and stimulation methods that will activate muscles selectively and independently with less implanted hardware. A practical functional neuromuscular stimulation (FNS) system may need to employ extraneural, intraneural,...
متن کاملRecruitment properties of intramuscular and nerve-trunk stimulating electrodes.
Functionally useful reanimation of paralyzed limbs generally requires reliable, finely graded control of muscle recruitment and force with minimal fatigue. We used force and electromyographic (EMG) recordings in combination with myofibrillar adenosine triphosphatase activity and glycogen depletion analysis to investigate the recruitment properties of intramuscular (IM) and nerve cuff (NC) stimu...
متن کاملDetermination of Chromium(III) and Magnesium(II) Ions in Pharmacological and Real Water Samples using Potentiometric Sensors based on Chitosan Schiff base Derivative as Green and Sensitive Ionophore
In the study, novel and sensitive carbon paste electrodes (CPEs) developed for thepotentiometric measurement of Cr(III) and Mg(II) ions in pharmacological and water samples.CPEs as indicator electrodes were prepared from a mixture of four components, includinggraphite powder, paraffin oil, multi-walled carbon nanotubes (MWCNTs), and a greenionophore (Chitosan Schiff base...
متن کاملFabrication of new carbon paste electrodes based on gold nano-particles self-assembled to mercapto compounds as suitable ionophores for potentiometric determination of Copper ions
In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 38 5 شماره
صفحات -
تاریخ انتشار 2001