Fast analysis of decabrominated diphenyl ether using low-pressure gas chromatography-electron-capture negative ionization mass spectrometry.

نویسندگان

  • Alin C Dirtu
  • Khaiwal Ravindra
  • Laurence Roosens
  • René van Grieken
  • Hugo Neels
  • Ronny Blust
  • Adrian Covaci
چکیده

This paper reports the applicability of low-pressure gas chromatography-mass spectrometry operated in electron-capture negative ionization mode (LP-GC-ECNI-MS) for the analysis of decabrominated diphenyl ether (BDE-209). Particular attention was paid to find optimal injector and oven conditions for minimal thermal degradation of BDE-209. The analytical characteristics were compared for LP-GC columns (10 m x 0.53 mm) with different film thicknesses (d(f) 0.15 microm versus 0.25microm) and for a conventional GC column (15 m x 0.25 mm, 0.10 microm d(f)). Short residence times (6.5 and 9.8 min) of BDE-209 were found for the LP-GC systems with 0.15 and 0.25microm d(f), respectively, resulting in a low elution temperature and minimal degradation. Additionally, baseline separation of 22 polybrominated diphenyl ether (PBDE) congeners (major components of PBDE technical mixtures) was possible in less than 12 min using the LP-GC-ECNI-MS system with 0.15microm d(f). The optimized method was applied for the determination of PBDEs in Belgian indoor dust samples. The obtained concentrations of BDE-209 (range 8-292 ng/g dry weight) were in the same range or lower than concentrations in dust from other European countries.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison and optimization of several pretreatment techniques for determination of decabrominated diphenyl ether in polymer samples by gas chromatography mass spectrometry.

A sensitive quantification of decabrominated diphenyl ether (deca-BDE) was achieved by optimizing the injection temperature, pressure and column system with gas chromatography mass spectrometry in selected ion monitoring mode. A simple one-step cleanup method with acid silica gel column chromatography showed the optimum efficiency and minimum matrix interference. Ultrasonic-assisted extraction ...

متن کامل

Determination of plasma bile acids by capillary gas-liquid chromatography-electron capture negative chemical ionization mass fragmentography.

Combined capillary gas-liquid chromatography-electron capture negative chemical ionization mass spectrometry of pentafluorobenzyl ester-TMSi ether derivatives of bile acids and isotope dilution using deuterated internal standards are introduced as a sensitive and selective analysis technique for plasma bile acids. As a result of the high ionization efficiency of pentafluorobenzyl derivatives un...

متن کامل

Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards.

A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use of (81)Br-labelled PBDEs for isotope dilution analysis and the measurement of (79)Br/(81)Br i...

متن کامل

Determination of PBDEs in human breast adipose tissues by gas chromatography coupled with triple quadrupole mass spectrometry.

The potential of gas chromatography/tandem mass spectrometry with a triple quadrupole analyzer for determination of 12 polybrominated diphenyl ethers in human breast tissues has been investigated. After extraction with hexane, two purification procedures-automated normal-phase high-performance liquid chromatography and solid-phase extraction-were assayed. Both electron impact ionization, in sel...

متن کامل

Analysis of platelet-activating factor by GC-MS after direct derivatization with pentafluorobenzoyl chloride and heptafluorobutyric anhydride.

Parallel analysis of platelet-activating factor (PAF) using chemical ionization gas chromatography-mass spectrometry after direct derivatization with pentafluorobenzoyl chloride (PFB) and heptafluorobutyric anhydride (HFB) provides a facile and highly sensitive means for detecting and elucidating the structure of the numerous alkyl-chain homologs of this acetylated phospholipid autacoid. In the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1186 1-2  شماره 

صفحات  -

تاریخ انتشار 2008