Time-and-motion tool for the assessment of working time in tuberculosis laboratories: a multicentre study

نویسندگان

  • V. Mathys
  • E. Roycroft
  • P. Raftery
  • R. Groenheit
  • D. B. Folkvardsen
  • D. Homorodean
  • E. Vasiliauskiene
  • L. Vasiliauskaite
  • C. Kodmon
  • M. J. van der Werf
  • F. Drobniewski
  • V. Nikolayevskyy
چکیده

SETTING Implementation of novel diagnostic assays in tuberculosis (TB) laboratory diagnosis requires effective management of time and resources. OBJECTIVE To further develop and assess at multiple centres a time-and-motion (T&M) tool as an objective means for recording the actual time spent on running laboratory assays. DESIGN Multicentre prospective study conducted in six European Union (EU) reference TB laboratories. RESULTS A total of 1060 specimens were tested using four laboratory assays. The number of specimens per batch varied from one to 60; a total of 64 recordings were performed. Theoretical hands-on times per specimen (TTPS) in h:min:s for Xpert® MTB/RIF, mycobacterial interspersed repetitive unit-variable number of tandem repeats genotyping, Ziehl-Neelsen staining and manual fluorescence microscopy were respectively 00:33:02 ± 00:12:32, 00:13:34 ± 00:03:11, 00:09:54 ± 00:00:53 and 00:06:23 ± 00:01:36. Variations between laboratories were predominantly linked to the time spent on reporting and administrative procedures. Processing specimens in batches could help save time in highly automated assays (e.g., line-probe) (TTPS 00:14:00 vs. 00:09:45 for batches comprising 7 and 31 specimens, respectively). CONCLUSIONS The T&M tool can be considered a universal and objective methodology contributing to workload assessment in TB diagnostic laboratories. Comparison of workload between laboratories could help laboratory managers justify their resource and personnel needs for the implementation of novel, time-saving, cost-effective technologies, as well as identify areas for improvement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and validation of a tool to assess the safety principles of working with nanomaterials in nanotechnology laboratories

Introduction: The unique properties of nanomaterials, in addition to their applications in science and technology, can be a threat to human health and the environment. Exposure to these materials may occur in workplaces or in research laboratories. It can be said that about half of people with occupational exposure to nanomaterials work in academic environments and laboratories. So, the present...

متن کامل

Administration of medical laboratories from the point of view of future managers

Management skills is required for all medical laboratories managers to work better and mane efficient, and assess the development of attaining the organizational goals. Moreover, the manager through having good reputation, adorned and justified appearance, honestly, foresight, for-sightedness and self-reliance, improve the influence rate on their employees. Using leadership styles, for example ...

متن کامل

Damage Assessment of Reinforced Concrete Buildings Considering Irregularities (RESEARCH NOTE)

Structural damage can be controlled in performance based seismic design (PBSD) according to the requirement under a certain hazard level. During strong ground motion (GM) such buildings suffer minor to major damages depending on the shaking level of GM. The available damage assessment methods are complex, tedious and time-consuming procedure. In the present study, a simplified empirical model h...

متن کامل

بررسی وضعیت اطمینان کیفیت در آزمایشگاه‌های محیطی و حد واسط در هفت استان کشور

Background and Aim: Peripheral and intermediate laboratories have an important role in diagnosis, treatment and prevention of tuberculosis. Today, without these laboratories, maintaining health and preventing the spread of tuberculosis is not possible. The aim of this study was Evaluation of manpower, equipment and quality control standards in peripheral and intermediate laboratories assessment...

متن کامل

Designing, Fabricating, and Testing the Validity and Reliability of the Digital Headband for Cervical Proprioception Assessment: A Descriptive Study

Background and Objectives: Accuracy of proprioceptive input plays an important role in cervical motor control. Several methods have been used to evaluate the accuracy of proprioceptive input as a factor of cervical injury prevention or rehabilitation. The aim of this study was to introduce a new tool for evaluating the accuracy of cervical proprioception and determine its validity and reliabili...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2018