Retention modelling in ternary solvent-strength gradient elution reversed-phase chromatography using 30 mm columns.
نویسندگان
چکیده
An optimization strategy for ternary solvent-strength gradient elution RP chromatography is described in which a two-dimensional model of gradient time (2 levels) against ternary proportions of organic modifiers (4 levels) was constructed. From the resolution surface the optimum ratio of organic modifiers could be selected. Excellent retention time and acceptable peak width and resolution simulations were obtained. The separation could be further optimized from the same input data by using a standard one-dimensional model in order to optimize for gradient slope, duration and shape. Excellent retention time and acceptable peak width and resolution simulations were obtained (< 1, 2 and 6% error, respectively).
منابع مشابه
EVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS
The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...
متن کاملUnderstanding the Complexity of Porous Graphitic Carbon (PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions Overcomes Loss of Retention and Reduces Variability
Porous graphitic carbon (PGC) is an important tool in a chromatographer's armory that retains polar compounds with mass spectrometry (MS)-compatible solvents. However, its applicability is severely limited by an unpredictable loss of retention, which can be attributed to contamination. The solutions offered fail to restore the original retention and our observations of retention time shifts of ...
متن کاملNew approach to linear gradient elution used for optimisation in reversed-phase liquid chromatography.
A new mathematical treatment concerning the gradient elution in reversed-phase liquid chromatography when the volume fraction psi of an organic modifier in the water-organic mobile phase varies linearly with time is presented. The experimental ln k versus psi curve, where k is the retention factor under isocratic conditions in a binary mobile phase, is subdivided into a finite number of linear ...
متن کاملHigh-temperature separations on a polymer-coated fibrous stationary phase in microcolumn liquid chromatography.
Novel polymer-coated fiber-packed microcolumns in liquid chromatography (LC) have been developed. Typical polymeric materials, such as polydimethylsiloxane and polyethyleneglycol, which are conventional stationary phases of capillary columns in gas chromatography (GC), have been employed as coating materials onto the surface of fine filaments. Packed longitudinally with a bundle of polymer-coat...
متن کاملApplication of Narrow-Bore HPLC Columns in Rapid Determination of Sildenafil Citrate in Its Pharmaceutical Dosage Forms
A special type of silica-based columns has been recently introduced into the market which is called narrow-bore columns. They have lower internal volume than the standard high-performance liquid chromatography (HPLC) columns and thus reduce the solvent consumption by almost 80%. A simple, accurate and environmentally friendly reversed phase- HPLC (RP-HPLC method) which could be used in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1121 2 شماره
صفحات -
تاریخ انتشار 2006