The Effect of Tube Wetting Rate on Kestner Performance at Sezela Factory

نویسنده

  • Sezela Kestner
چکیده

Sezela sugar factory uses long tube climbing film evaporators of the Kestner type for first effect evaporation. The plant trial showed that the Kestner specific evaporation rate (kg/m/h) and heat transfer coefficient can be improved by increasing the tube wetting rate (kg/min/tube). Increasing the wetting rate by 62% increased the specific evaporation rate by 40%. Introduction The climbing film evaporator was patented in 1899 by Paul Kestner. These long tubed vessels, typically 7 m in height, are common in the South African sugar industry and are referred to as Kestners. Kestners are typically used as first and second effect vessels in multiple effect evaporator stations. The authors are not aware of Kestners being used as third, fourth or fifth effects in South Africa. Although common in the local sugar industry, the performance of Kestners has been inconsistent. However, the Umzimkulu Kestner is viewed as a benchmark by the authors. The Umzimkulu Kestner has good evaporation rates and low fouling rates, and can operate for up to eight weeks without any tube cleaning. The Sezela Kestners, on the other hand, produce lower evaporation rates and higher fouling rates. The Kestners are cleaned on a two-week cycle. The Kestners also have a history of blocked tubes due to juice drying out in the tubes. Kestner performance has been studied by a number of South African authors. The studies were mainly on pilot Kestners. James et al. (1978) found that the heat transfer coefficient (HTC) increased with feed rate. This paper also quotes a specific evaporation rate of 35 to 40 kg/m/h. Walthew and Whitelaw (1996) also studied Kestner performance in a pilot plant and showed that increasing the feedrate increased HTC and decreased the fouling rate. The Umzimkulu (UK) and Sezela (SZ) Kestner design data, together with the current operating data, are given in Table 1. The comparison of specific evaporation rates shows that the UK Kestner performs better by approximately 26%. The tube wetting rate is also higher in the UK Kestner. The authors attempted to simulate the UK Kestner wetting rate on one of the SZ Kestners. Proc S Afr Sug Technol Ass (2008) 81: 184 189

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat Transfer, Mass Transfer and Scaling Characteristics in a Long Tube, Climbing Film, Pilot Plant Evaporator

ing characteristics could be investigated. Finally the pilot plant A single tube plant Kestner evaporator'was set up at was run under 1st effect conditions in order that a comparison Illovo to investigate heat transfer characteristics when could be made with industrial 1st effect evaporators (both simulating different evaporator Tests carried out have Roberts and Kestner). This particular trial...

متن کامل

Effect of baffle oientation on shell tube heat exchanger performance

In this paper, fluid flow and heat transfer in the laboratory (small size) shell tube heat exchanger are analysed by computational fluid dynamic software. In this type of shell tube heat exchanger baffles with different angles of rotation: 00 (horizontal segmental baffle), 150 (from horizontal), 300, 450, 600, 750, 900 (vertical segmental baffle) is used. Effect of baffle orientation on shell t...

متن کامل

Experimental investigation of thermal and electrical performances of a nanofluid-cooled photovoltaic/thermal system equipped with a sheet-and-grooved serpentine tube collector

Introduction: In the present experimental investigation, the thermal and electrical performances of a photovoltaic/thermal system equipped with a sheet-and-grooved serpentine tube collector are investigated. The water-magnetite nanofluid is used as the heat transfer fluid. The effect of nanoparticle volume concentration (0-1%), nanofluid mass flow rate (10-40 kg/h) and groove pitch (0, 0.54 an...

متن کامل

Development of Low Cost Carbon Steel Tube for Sugar Mill Evaporators in South Africa

Due to the recent droughts, the retube of Sezela evaporators was delayed for a few years, resulting in a need for a low cost carbon steel tube to retube five evaporators. A recent failure highlighted the importance of the heat treatment and expansion characteristics of these tubes. This paper discusses the failure of a carbon steel tube, the development of the heat treatment of locally manufact...

متن کامل

Experimental Study of Heat Transfer Rate in a Shell and Tube Heat Exchanger with Air Bubble Injection (TECHNICAL NOTE)

Shell and tube heat exchangers are widely being used in many of industrial and power engineering applications. Different techniques have been employed in order to enhance the performance of the heat exchanger. Air bubble injection is one method to increase the turbulence of the flowing fluids which in turn enhance the heat transfer performance. Injecting air bubbles is one of the promising tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008