Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms.
نویسندگان
چکیده
Subjective estimates of the angiographic severity of coronary artery stenoses show variability and inaccuracy. We therefore tested the accuracy of a newly developed computerized image analysis system for quantitating vessel diameter from cineangiograms. Fourteen cylindrical phantoms of known diameter were filled with contrast medium and filmed over a wide range of clinically relevant radiographic conditions in order to develop regression equations that related computer-derived to anatomic diameters. Computer measurements of vessel diameter were unaffected by vessel size, magnification, focal spot size, thickness of scattering medium, kilovolt peak, or location within the radiographic field, but a correction factor was necessary for a small but significant (p less than .01) linear dependence on contrast medium concentration. The accuracy of computerized vessel diameter measurements ranged between +/- 59 and +/- 137 mu for all conditions except for rapid vessel motion and contrast medium concentrations of 50% or less meglumine diatrizoate (Renografin 76), both of which resulted in reduced accuracy as well as in the inability to locate lumen edges of vessels less than 1 mm in diameter.
منابع مشابه
CORONARY ARTERY DISEASE Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms
Subjective estimates of the angiographic severity of coronary artery stenoses show variability and inaccuracy. We therefore tested the accuracy of a newly developed computerized image analysis system for quantitating vessel diameter from cineangiograms. Fourteen cylindrical phantoms of known diameter were filled with contrast medium and filmed over a wide range of clinically relevant radiograph...
متن کاملLaboratory Investigation Coronary Artery Disease
Subjective estimates of the angiographic severity of coronary artery stenoses show variability and inaccuracy. We therefore tested the accuracy of a newly developed computerized image analysis system for quantitating vessel diameter from cineangiograms. Fourteen cylindrical phantoms of known diameter were filled with contrast medium and filmed over a wide range of clinically relevant radiograph...
متن کاملAutomatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملAssessment of immediate and long-term functional results of percutaneous transluminal coronary angioplasty.
Assessment of the functional significance of coronary artery lesions during cardiac catheterization has recently become possible by calculating coronary flow reserve from both myocardial contrast appearance time and density in the resting and hyperemic states determined from digitized coronary cineangiograms. However, the interobserver and intraobserver variabilities, as well as the short-, med...
متن کاملAccuracy and robustness of a simple algorithm to measure vessel diameter from B-mode ultrasound images.
Measurement of changes in arterial vessel diameter can be used to assess the state of cardiovascular health, but the use of such measurements as biomarkers is contingent upon the accuracy and robustness of the measurement. This work presents a simple algorithm for measuring diameter from B-mode images derived from vascular ultrasound. The algorithm is based upon Gaussian curve fitting and a Vit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 68 2 شماره
صفحات -
تاریخ انتشار 1983