An investigation of friction-based tendon sheath model appropriate for control purposes

نویسندگان

  • T. N. Do
  • T. Tjahjowidodo
  • S. J. Phee
چکیده

The tendon sheath mechanism plays an important role in many robotic systems from surgical devices to robot hands. However, many unexpected properties such as nonlinear hysteresis and backlash, which appear in the tendon sheath system, cause major losses in force transmission. This report deals with the characterization of hysteresis phenomenon, which is attributed to the presence of frictional effects on its elements, in a tendon-sheath driven surgical robot. Unlike various approaches presented in the literature that utilized multiple lumped mass elements, this proposed approach models the tendon sheath as one element. A new dynamic friction model that allows accurate description of friction lag and hysteresis behavior in two regimes, i.e. presliding and sliding regimes, for a sheath in arbitrary configuration such as helical and spatial shape has been developed. In both regimes, an advanced set of velocity and acceleration dependent functions in a form of the Stribeck function and the modified normalized Bouc–Wen model are used to model friction characteristics between the tendon and the sheath. The smooth transition between the two regimes is also assured. The proposed model is subsequently validated using experimental data. It shows a high degree of accuracy and fidelity in predicting the friction force in a tendon-sheath mechanism. The proposed model overcomes the current drawbacks in tendon sheath friction modeling approach when dealing with discontinuity as the system operates near areas of zero velocity. The new structure of this new model allows a simplified calculation, bringing more valuable practicability and providing an accurate prediction for haptic feedback and control purposes. & 2013 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonlinear Modeling and Parameter Identification of Dynamic Friction Model in Tendon Sheath for Flexible Endoscopic Systems

Minimally Invasive Surgery (MIS) has established a revolution in surgical communities, with its many advantages over open surgery. The need of more simplicity and high maneuverability makes the tendon sheath a very suitable mechanism in flexible endoscopic systems. Due to the restriction on size constraints and sterilization problems, traditional sensors cannot be mounted on the tool tips of a ...

متن کامل

Performance Control of Tendon-Driven Endoscopic Surgical Robots With Friction and Hysteresis

In this study, a new position control scheme for the tendon-sheath mechanism (TSM) which is used in flexible medical devices is presented. TSM is widely used in dexterous robotic applications because it can flexibly work in limited space, in constrained environments, and provides efficient power transmission from the external actuator to the distal joint. However, nonlinearities from friction a...

متن کامل

A new approach of friction model for tendon-sheath actuated surgical systems: Nonlinear modelling and parameter identification

Article history: Received 23 September 2013 Received in revised form 4 November 2014 Accepted 8 November 2014 Available online 22 November 2014 Nonlinear friction in tendon-sheath mechanism (TSM) introduces difficulties in predicting the end-effector force inside the human body during surgical procedures. This brings a critical challenge for surgical robots that need high fidelity in haptic dev...

متن کامل

Intra-articular Fibroma of Tendon Sheath in Knee Joint Associated with Iliotibial Band Friction Syndrome: Rare Occurrence in a Teenage Girl

INTRODUCTION Iliotibial band (ITB) friction syndrome is a common overuse injury typically seen in active athlete population. A nodular lesion on the inner side of the ITB as an etiology or an accompanying lesion with friction syndrome has rarely been reported. Among such nodular lesions around knee, fibroma of tendon sheath (FTS) is a rare occurrence. All the more intra-articular occurrence is ...

متن کامل

Intra-Articular Fibroma of Tendon Sheath in a Knee Joint Associated with Iliotibial Band Friction Syndrome

Iliotibial band (ITB) friction syndrome is a common overuse injury typically seen in the active athlete population. A nodular lesion on the inner side of the ITB as an etiology or an accompanying lesion from friction syndrome has been rarely reported. A 45-year-old male presented with recurrent pain and a movable nodule at the lateral joint area, diagnosed as ITB friction syndrome. The nodule w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013