We describe the design and implementation of a generic robotic solution to automate the loading of MALDI sample plates into a mass spectrometer. The soft- and hardware aspects are described together with the various safety issues that need to be addressed. The automation increases throughput by a factor of between 5- and 80-fold.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated integration of monolith-based protein separation with on-plate digestion for mass spectrometric analysis of esophageal adenocarcinoma human epithelial samples.

A unique approach of automating the integration of monolithic capillary HPLC-based protein separation and on-plate digestion for subsequent MALDI-MS analysis has been developed. All liquid-handling procedures were performed using a robotic module. This automated high-throughput method minimizes the amount of time and extensive labor required for traditional in-solution digestion followed by exh...

متن کامل

Nanoliter sample handling combined with microspot MALDI-MS for detection of gel-separated phosphoproteins.

We describe a microspot matrix-assisted laser desorption ionization (MALDI) mass spectrometric approach to analyze gel-separated phosphoproteins. This method involves in-gel digestion of phosphoproteins after gel separation, followed by open tubular capillary (OTC) immobilized metal-ion affinity chromatography (IMAC) to capture the phosphopeptides with markedly reduced interferences from nonpho...

متن کامل

Microscale sample deposition onto hydrophobic target plates for trace level detection of neuropeptides in brain tissue by MALDI-MS.

A sample preparation method that combines a modified target plate with a nanoscale reversed-phase column (nanocolumn) was developed for detection of neuropeptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). A gold-coated MALDI plate was modified with an octadecanethiol (ODT) self-assembled monolayer to create a hydrophobic surface that could c...

متن کامل

Electrospray sample deposition for matrix-assisted laser desorption/ionization (MALDI) and atmospheric pressure MALDI mass spectrometry with attomole detection limits.

Electrospray sample deposition was explored for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). In this method, nanoliter volumes of matrix/analyte mixture were electrosprayed from a high voltage biased (1-2 kV) fused-silica capillary onto a grounded MALDI plate mounted 100-500 microm from the capillary outlet. Electrospray deposition with these condi...

متن کامل

Magnetic nanoparticle-based platform for characterization of histidine-rich proteins and peptides.

In this study, we developed a platform that can be used to rapidly enrich polyhistidine(His)-tagged proteins/peptides from complex samples selectively using the Fe3O4@Al2O3 magnetic nanoparticles (MNPs) as the affinity probes. At pH 7, the dissociation constant between poly-His, i.e., His6, and the Fe3O4@Al2O3 MNPs was ~10(-5) M and the trapping capacity was ~100 nmol/mg for His6. Enrichment wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of proteome research

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2007