Failure of spinal anesthesia with marcaine (bupivacaine): recent cluster of cases.
نویسنده
چکیده
Spinal anesthesia has been used for over a century and has gained popularity, particularly in the past few decades, as an excellent approach in obstetrics and certain postoperative situations. The published failure rate for spinal anesthesia is less than 3%, but in that report, failure was defined as “failure to develop an adequate block despite successful dural puncture”, and the cases would thus have included partial or incomplete block. The incidence of complete failure of spinal block (with no sensory or motor block), despite cerebrospinal fluid flow, is substantially lower. A variety of factors have been implicated in failure of spinal block, including movement of the needle during injection, large intrathecal volume, technical errors, miscalculation of the dose, maldistribution of the local anesthetic, presence of extradural cysts, and anatomic sacral restriction. In June and July 2008, a cluster of 3 cases of complete failure of spinal block after spinal administration of 0.75% Marcaine (bupivacaine; lot 64095DD, expiry April 1, 2011 [20110401]) occurred at our site. The cases were reported to the manufacturer, Hospira Healthcare Corporation. In these 3 cases, the anesthesia was performed by 2 different experienced anesthesiologists using a standard technique (aseptic technique, infiltration with lidocaine 1%, aspiration of cerebrospinal fluid at the beginning and end of injection). My colleagues and I are aware of 5 similar cases of partially or completely ineffective spinal block with the same drug at 2 other area hospitals within the past few months (lot 67120DD, expiry July 1, 2011 [20110701]). It appears to us that there has been a recent increase in the incidence of spinal-block failure. We have reported one of these recent cases of complete failure, which occurred at our affiliated hospital, to Hospira and to the Canada Vigilance Regional Office of Health Canada. Hospira has stated that the reported lots (64095DD and 67120DD) met all manufacturing specifications. Clusters of inadequate spinal anesthesia have previously been reported in the literature. In one of the largest clusters, reported by Smiley and Redai, 11 cases of either inadequate or completely failed spinal block despite cerebrospinal fluid flow occurred in a 7-month period. Our recent cluster of cases of complete failure of spinal anesthesia, as well as similar experiences at other institutions, is of great concern. Centres are encouraged to report all cases of failed spinal block with spinal Marcaine to the manufacturer (Hospira, 1-866-488-6088; choose option 7) and to Health Canada (1-866-234-2345 or online at http://www.healthcanada.gc.ca/medeffect). In addition, my colleagues and I would be interested to hear from anyone who has had a similar experience recently and from anyone who can provide a possible explanation.
منابع مشابه
The Comparison of Clinical, Histopathological and some Hemodynamic Effects of Spinal Anesthesia Applied in Dogs Through Bupivacaine HCl and Ropivacaine HCl in Two Different Concentrations
The aim of this study was to evaluate the side effects of local and systemic clinical, histopathological and hemodynamics by use of isobaric and hyperbaric bupivacaine in different concentrations during spinal anesthesia which has been a common use within the past few years. The study material consisted of 23 healthy stray dogs with dissimilar sex, age and body weight as well as bupivacaine hyd...
متن کاملبررسی مقایسه طول دوره ریکاوری، عوارض گوارشی و تنفسی در بیحسی نخاعی با مارکائین هیپربار در بیماران دیابتی و غیردیابتی
Introduction: Spinal anesthesia via Marcaine hyperbaric in different patients is associated with different side effects. The present study was performed to detect recovery period, Gastrointestinal and Respiratory side effects in spinal anesthesia with hyperbaric marcaine in diabetic and non diabetic patients. Methods: In this comparative study, 62 patients (30 diabetic and 32 non-diabetics) wi...
متن کاملMINIDOSE BUPIVACAINE – FENTANYL SPINAL ANESTHESIA FOR CESAREAN SECTION IN PREECLAMPTIC PARTURIENTS
ABSTRACT Background: Spinal anesthesia for cesarean section is associated with a high incidence of hypotension. The synergism between intrathecal opioids and local anesthetics may make it possible to achieve reliable spinal anesthesia with minimal hypotension using a minidose of local anesthetic. Methods: Forty-four preeclamptic parturients undergoing cesarean section were randomized in two gr...
متن کاملEffects of adding 5 mg meperidine to 10 mg bupivacaine for spinal anesthesia on postoperative pain in cesarean section surgery
Introduction: Meperidine has the advantages of being widely available and inexpensive. It would be highly cost-benefit if it is used at doses that are without any side-effect. Thus, this study aimed to assess the effect of meperidine 5 mg as an additive to bupivacaine for spinal anesthesia on postoperative pain in cesarean section surgery. Methods: This double-blind randomized clinical trial w...
متن کاملمقاومت حقیقی به داروهای بیحس کننده موضعی: (گزارش مورد)
Background: We report a case with apparent resistance to local anesthetics. While regional anesthetics failure are often attributed to technical failure, the clinical presentation and medical history of this patient suggests a true resistance to local anesthetics. Case report: A 28 years old man was scheduled for elective orthopedic surgery for right sided tibial bone fracture, and decision of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Canadian journal of hospital pharmacy
دوره 62 3 شماره
صفحات -
تاریخ انتشار 2009