Total arch replacement with an open stent graft for acute type A aortic dissection: fate of the false lumen.

نویسندگان

  • Naomichi Uchida
  • Hidenori Shibamura
  • Akira Katayama
  • Norimitsu Shimada
  • Miwa Sutoh
چکیده

OBJECTIVE To describe the fate of the false lumen remaining in the descending thoracic aorta after extensive primary repair of the thoracic aorta by the modified elephant trunk technique with a stent graft for acute type A aortic dissection, particularly the changes of the false lumen on enhanced CT scanning. METHODS The subjects were 65 consecutive patients who received arch replacement with an open stent graft for type A acute aortic dissection. CT scanning was performed at 1, 3, 12, 36, and 60 months postoperatively to detect thrombus formation, absorption of thrombus, and obliteration of the false lumen after its exclusion by the stent graft. The aorta was measured at four levels, which were the distal border of the stent graft, the middle and distal parts of the descending thoracic aorta, and the origin of the superior mesenteric artery. RESULTS Obliteration was recognized in all patients at the distal border of the stent graft and absorption of thrombus was seen in 90% at the middle of the descending thoracic aorta within 1 year after surgery. However, the false lumen remained patent at the superior mesenteric artery (SMA) level in 50% of the patients. CONCLUSIONS In patients with acute type A aortic dissection, it is possible to perform extensive primary repair of the thoracic aorta with relative safety by stent grafting, and this method may reduce the necessity for further operations to manage a residual false lumen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiovascular Surgery Total Arch Repair for Acute Type A Aortic Dissection With 2 Modified Techniques: Open Single-Branched Stent Graft Placement and Reinforcement of the Dissected Arch Vessel Stump With Stent Graft

Background—In total arch replacement for patients with acute type A aortic dissection, anastomoses of the graft to the left subclavian artery and descending aorta are often difficult, and the arch vessel anastomosis is frequently performed at the site of dissection. To make this procedure easier and safer, we developed 2 modified techniques: open single-branched stent graft placement into the l...

متن کامل

Descending endografts for type A dissections: con.

An important goal of surgical repair of type A aortic dissection is to resect the intimal tear. Studies on the fate of residual dissection after acute type A aortic dissection repair in the past decade have driven surgeons to seek procedures to avoid distal reoperation. Aggressive surgical approach with total arch replacement in acute type A dissection has demonstrated lower incidence of distal...

متن کامل

Total arch repair for acute type A aortic dissection with open placement of a modified triple-branched stent graft and the arch open technique

BACKGROUND In total arch repair with open placement of a triple-branched stent graft for acute type A aortic dissection, the diameters of the native arch vessels and the distances between 2 neighboring arch vessels did not always match the available sizes of the triple-branched stent grafts, and insertion of the triple-branched stent graft through the distal ascending aortic incision was not ea...

متن کامل

Hybrid antegrade repair of the arch and descending thoracic aorta with a new integrated stent-Dacron graft in acute type A aortic dissection: a look into the future with new devices.

A young male patient underwent supracoronary replacement of the ascending aorta for acute type A dissection under hypothermic circulatory arrest. After discharge, he was readmitted two weeks later due to severe aortic regurgitation and acute arch redissection. Under a second period of hypothermic circulatory arrest three weeks after the initial operation, radical treatment with aortic valve rep...

متن کامل

Should the “ elephant trunk ” be skeletonized ? Total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissection

文章来源:Acquired Cardiovascular Objectives: To eliminate the residual false lumen in the descending thoracic aorta and improve long-term outcomes of surgical intervention for Stanford type A aortic dissection, we performed the skeletonized “elephant trunk” procedure in the ascending aorta and aortic arch replacement combined with transaortic stented graft implantation into the descending aorta for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 2009