A Dual Pressure Linear Ion Trap Orbitrap Instrument with Very High Sequencing Speed*
نویسندگان
چکیده
Since its introduction a few years ago, the linear ion trap Orbitrap (LTQ Orbitrap) instrument has become a powerful tool in proteomics research. For high resolution mass spectrometry measurements ions are accumulated in the linear ion trap and passed on to the Orbitrap analyzer. Simultaneously with acquisition of this signal, the major peaks are isolated in turn, fragmented and recorded at high sensitivity in the linear ion trap, combining the strengths of both mass analyzer technologies. Here we describe a next generation LTQ Orbitrap system termed Velos, with significantly increased sensitivity and scan speed. This is achieved by a vacuum interface using a stacked ring radio frequency ion guide with 10-fold higher transfer efficiency in MS/MS mode and 3-5-fold in full scan spectra, by a dual pressure ion trap configuration, and by reduction of overhead times between scans. The first ion trap efficiently captures and fragments ions at relatively high pressure whereas the second ion trap realizes extremely fast scan speeds at reduced pressure. Ion injection times for MS/MS are predicted from full scans instead of performing automatic gain control scans. Together these improvements routinely enable acquisition of up to ten fragmentation spectra per second. Furthermore, an improved higher-energy collisional dissociation cell with increased ion extraction capabilities was implemented. Higher-collision energy dissociation with high mass accuracy Orbitrap readout is as sensitive as ion trap MS/MS scans in the previous generation of the instrument.
منابع مشابه
Ultra High Resolution Linear Ion Trap Orbitrap Mass Spectrometer (Orbitrap Elite) Facilitates Top Down LC MS/MS and Versatile Peptide Fragmentation Modes*
Although only a few years old, the combination of a linear ion trap with an Orbitrap analyzer has become one of the standard mass spectrometers to characterize proteins and proteomes. Here we describe a novel version of this instrument family, the Orbitrap Elite, which is improved in three main areas. The ion transfer optics has an ion path that blocks the line of sight to achieve more robust o...
متن کاملOrbitrap mass spectrometry: instrumentation, ion motion and applications.
Since its introduction, the orbitrap has proven to be a robust mass analyzer that can routinely deliver high resolving power and mass accuracy. Unlike conventional ion traps such as the Paul and Penning traps, the orbitrap uses only electrostatic fields to confine and to analyze injected ion populations. In addition, its relatively low cost, simple design and high space-charge capacity make it ...
متن کاملImplementation of electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer.
We describe the adaptation of a hybrid quadrupole linear ion trap-orbitrap mass spectrometer to accommodate electron-transfer ion/ion reactions (ETD) for peptide and protein characterization. The method utilizes pulsed, dual electrospray ion sources and requires minimal instrument modification. Switching between cation and reagent anion injection schemes is automated and accomplished within a f...
متن کاملTop-down protein sequencing and MS3 on a hybrid linear quadrupole ion trap-orbitrap mass spectrometer.
Top-down proteomics, the analysis of intact proteins (instead of first digesting them to peptides), has the potential to become a powerful tool for mass spectrometric protein characterization. Requirements for extremely high mass resolution, accuracy, and ability to efficiently fragment large ions have often limited top-down analyses to custom built FT-ICR mass analyzers. Here we explore the hy...
متن کاملProteomics on an Orbitrap Benchtop Mass Spectrometer Using All-ion Fragmentation*
The orbitrap mass analyzer combines high sensitivity, high resolution, and high mass accuracy in a compact format. In proteomics applications, it is used in a hybrid configuration with a linear ion trap (LTQ-Orbitrap) where the linear trap quadrupole (LTQ) accumulates, isolates, and fragments peptide ions. Alternatively, isolated ions can be fragmented by higher energy collisional dissociation....