Multislice computed tomography angiography as an imaging modality of choice in patients with suspicion of pulmonary embolism - own experiences and modern imaging techniques.
نویسندگان
چکیده
BACKGROUND Pulmonary embolism (PE) is a relatively common and potentially life threatening clinical condition with estimated prevalence to be 0.4%. Early diagnosis of PE followed by adequate treatment reduces the risk of major complications. Multislice computed tomography pulmonary angiography (CTPA) currently constitutes an imaging modality of choice in patients with suspicion of PE. Computed tomography venography (CTV) of lower limb veins and CTPA can be performed simultaneously, allowing for visualization of lower limb deep vein thrombosis (DVT). Additionally, dual energy CT scanners enable the evaluation of lung perfusion which is of high value in indirect detection of pulmonary arterial microembolisms. OBJECTIVES The goal of the study was to assess the diagnostic value of a 64-detector CT scanner in the detection of both acute and chronic PE in patients with clinical suspicion of PE based on clinical scores. MATERIAL AND METHODS Retrospective analysis of CTPA performed between 2010 and 2012 in 102 consecutive patients (64 women, 38 men) with clinical suspicion of PE based on clinical scores (first of all the Wells score) and elevated D-dimer level was carried out. The patients' median age was 68.9 (range between 34 and 91). The examinations were carried out with a 64-detector CT scanner, using a "pulmonary embolism" protocol. The volume of contrast agent ranged from 60 to 70 mL, depending on the patient's body mass. The contrast medium was administered with an injection rate 4.0-5.0 mL/s. The concentration of the contrast medium in the main pulmonary artery (MPA) was monitored in every case with the use of a 'smart-prep' method. Scanning was started a few seconds (4-6) after reaching a plateau by the contrast medium in MPA. Additionally, in selected patients CTV was performed and/or lung perfusion was evaluated. RESULTS Evidence of PE was demonstrated in 32 of 102 (31.4%) analyzed patients (pts). In 19 patients, centrally localized clots were visualized. Additionally, in 32 patients, lobar, segmental and proximal subsegmental filling defects corresponding to thrombo-embolic material were demonstrated. Moreover, in 14 patients, distal subsegmental filling defects were shown. Alternative diagnoses included: heart failure-related congestion (21 pts), pneumonia (19 pts) and malignancy (5 pts). CONCLUSIONS The multislice CTPA is an extremely useful imaging modality in patients with clinical suspicion of PE. The examination enables not only the analysis of pulmonary vessels but also evaluation of pulmonary parenchyma and mediastinum. The collimation of 0.625 mm makes it possible to detect the small foci of peripheral embolism.
منابع مشابه
Incidental Findings in Patients Evaluated for Pulmonary Embolism Using Computed Tomography Angiography
Introduction: Pulmonary embolism (PE) is a common lethal disease that its clinical symptoms may be seen in many other diseases. Computed tomography pulmonary angiography (CTPA) is a valuable diagnostic modality for detection of PE. In addition, it can accurately detect the other diseases with clinical symptoms similar to PE. The aim of this study is to evaluate the frequency of PE and nonemboli...
متن کاملEvaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography
Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملProfile of patients referred for computed tomography, likely to be explored by scintigraphy imaging in a country with no nuclear medicine service: The case of Togo
Introduction: Describe the profile of patients referred for computed tomography (CT) likely to be scanned with scintigraphy imaging in Togo. Methods: Prospective study carried out from May 15 to August 15 2020 including patients referred for non-traumatic CT scans (excluding strokes) in all the radiology centres in Togo with operational ...
متن کاملBimodal magnetic resonance imaging-computed tomography nanoprobes: A Review
Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Advances in clinical and experimental medicine : official organ Wroclaw Medical University
دوره 22 5 شماره
صفحات -
تاریخ انتشار 2013