Impact of Static and Dynamic Load Model on the Low Voltage Ride- Through of the Doubly-Fed Induction Generator Wind Farm
نویسندگان
چکیده
The increasing penetration of load model in distribution systems may significantly affect voltage stability of the systems, particularly during Low Voltage Ride-Through (LVRT) wind turbine. The main objective of this work is to present the impact of different static and dynamic load models, on the LVRT recovery after disturbances. A component and composite loading structures are considered, comprising static, dynamic motor and a composite model. Motor loads are assessed with respect to their mechanical loads. The polynomial load model using load class and load type is investigated thoroughly under various operating conditions. The present paper examines the effect of nonlinear loads as well as different mechanical torque and inertia of induction motor loads on the transient stability and observing the fault recovery performance of the Doubly-Fed Induction Generator (DFIG) wind turbine system. The dynamic impacts between wind turbines (WTs) and motor loads are also examined. The complete system is modeled and simulated using PSAT/MATLAB software environment in such a way that it can be suited for modeling of all types of loads configurations. The LVRT capability is investigated and the results of voltage dip ride-through simulations are presented for both static and dynamic load. Key-Words: Low Voltage Ride-Through, doubly-fed induction generator wind turbine, static load, dynamic load, composite load modeling, transient stability.
منابع مشابه
Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES
Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...
متن کاملA New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter
In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...
متن کاملImproving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller
Using the FACTS controllers, such as static synchronous compensator (STATCOM), as it provides continuous reactive power, in the grid including wind turbine (WT) equipped with doubly fed induction generator, for improving voltage profile (under normal circumstances) and providing a transition ability from inductor generator transition state has been proposed. In this paper, in order to contr...
متن کاملImproving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller
Using the FACTS controllers, such as static synchronous compensator (STATCOM), as it provides continuous reactive power, in the grid including wind turbine (WT) equipped with doubly fed induction generator, for improving voltage profile (under normal circumstances) and providing a transition ability from inductor generator transition state has been proposed. In this paper, in order to contr...
متن کاملSliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition
This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...
متن کامل