Quality assurance measurements for high‐dose‐rate brachytherapy without film

نویسنده

  • Paul A. Jursinic
چکیده

The purpose of this study was to develop new and modified tools that allow HDR brachytherapy quality assurance tests to be carried out efficiently without film, video cameras, stopwatches, and mechanical rulers; and to devise methods that use these new tools for daily and quarterly check procedures, which are efficient and provide increased accuracy compared to previous methods. The HDR brachytherapy system tested was the GammaMedplus iX, Ir-192 HDR. Various catheters and treatment applicators designed for this system were tested. To measure the absolute position of the source, a simple tool was built that uses a Plexiglas frame, a template for applicator positioning, and a diode for radiation detection. For daily reproducibility and source strength tests, modifications were made of a Model 70008, HDR brachytherapy Ir-192 quality assurance tool, which is used with the HDR-1000-Plus well-type reentrant chamber. Measurement procedures and analysis protocols were developed that use the Microsoft Excel spreadsheet program. Independent determination of source positions was made with a computer video camera and radiochromic film. Using the new tool, for a straight catheter the measured source position is found to be within ± 0.1 mm of the mechanically set distance, for a ring applicator ± 0.3 mm, for a tandem ± 0.2 mm, and for an ovoid ± 0.2 mm. Using the modified insert, daily dwell position can be determined with an accuracy of 0.3 mm and timer accuracy can be determined with an accuracy of 0.3% over a 20 s time frame. The time needed to carry out quarterly tests is estimated to be reduced by two- to four-fold compared to previous methods. New and modified equipment and procedures have been developed for measuring HDR brachytherapy dwell position and dwell times efficiently with high accuracy. The equipment described in this work can be built and modifications can be made in most clinics. Location of dwell position can be determined in straight catheters and ring and ovoid applicators. Timer linearity and accuracy can be determined. Source strength can be confirmed. Measurement efficiency is improved compared to previous methods that used film, video cameras, mechanical rulers, and stopwatches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy

Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...

متن کامل

Quality assurance prusedore in high dose rate bracythrapy

Introduction: Quality assurance is essential for obtaining the best achievable tumor control, avoiding unnecessary side effects, accuracy and safety during performing High Dose Rate (HDR) Brachytherapy (BT). Quality assurance is extremely important because HDR BT procedures are performed quickly, with high doses given in a short time period, with little opportunity for correcti...

متن کامل

Developing a Verification and Training Phantom for Gynecological Brachytherapy System

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

متن کامل

A novel phantom design for brachytherapy quality assurance

Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...

متن کامل

Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014