An Evaluation of Transcutaneous Carbon Dioxide Partial Pressure Monitoring during Apnea Testing in Brain-dead Patients

ثبت نشده
چکیده

Background: Diagnosis of brain death usually requires an arterial carbon dioxide partial pressure (PaCO2) of 60 mmHg during the apnea test, but the increase in PaCO2 is unpredictable. The authors evaluated whether transcutaneous carbon dioxide partial pressure (PtcCO2) monitoring during apnea test can predict that a PaCO2 of 60 mmHg has been reached. Methods: The authors compared PtcCO2 measured with a transcutaneous ear sensor (V-Sign Sensor, Sentec Digital Monitoring System; SENTEC-AG, Therwil, Switzerland) and PaCO2 obtained from arterial blood gas measurements in 32 clinically brain-dead patients. Results: In the first 20 patients, the mean PaCO2–PtcCO2 gradient was 0.7 3.6 mmHg at baseline and 8.7 7.1 mmHg after 20 min of apnea. Using receiver operating characteristic curve analysis (area under the curve: 0.983 0.013), the best threshold value of PtcCO2 to predict that a PaCO2 of 60 mmHg had been reached was 60 mmHg (positive predictive value: 1.00 [0.93– 1.00]). In the following 12 patients investigated with use of this PtcCO2 target value of 60 mmHg, the mean duration of the apnea test (11 4 vs. 20 0 min; P < 0.001), hypercapnia (74.0 4.9 vs. 98.3 20.0 mmHg; P < 0.001), acidosis (pH: 7.18 0.06 vs. 7.11 0.08; P < 0.001), and decrease in arterial oxygen partial pressure ( 47 44 vs. 95 89; P < 0.05) at the end of the test were reduced as compared with the 20-min apnea test group. Conclusion: During the apnea test in brain-dead patients, a PtcCO2 of 60 mmHg accurately predicts that a PaCO2 of 60 mmHg has been reached. This may allow a reduction in the duration of the apnea test and consecutively limit occurrence of complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of transcutaneous carbon dioxide partial pressure monitoring during apnea testing in brain-dead patients.

BACKGROUND Diagnosis of brain death usually requires an arterial carbon dioxide partial pressure (Paco2) of 60 mmHg during the apnea test, but the increase in Paco2 is unpredictable. The authors evaluated whether transcutaneous carbon dioxide partial pressure (Ptcco2) monitoring during apnea test can predict that a Paco2 of 60 mmHg has been reached. METHODS The authors compared Ptcco2 measure...

متن کامل

The usefulness of end-tidal carbon dioxide monitoring during apnea test in brain-dead patients

BACKGROUND The apnea test (AT) is essential to confirming the diagnosis of brain death, but critical complications can occur if the AT is maintained over a long period. To minimize the AT period, we used end-tidal carbon dioxide (ETCO2) monitoring because ETCO2 is closely correlated with partial pressure of arterial carbon dioxide (PaCO2). The aim of the present study is to evaluate the usefuln...

متن کامل

The accuracy of non-invasive carbon dioxide monitoring: a clinical evaluation of two transcutaneous systems.

We determined the accuracy of two transcutaneous carbon dioxide monitoring systems (SenTec Digital Monitor with V-Sign Sensor and TOSCA 500 with TOSCA Sensor 92) for the measurement of single values and trends in the arterial partial pressure of carbon dioxide in 122 adult patients during major surgery and in 50 adult patients in the intensive care unit. One or several paired measurements were ...

متن کامل

End-tidal carbon dioxide and transcutaneous carbon dioxide monitoring during neonatal transport

Abbreviations: CO2, Carbon dioxide; PaCO2, Arterial partial pressure of carbon dioxide; PtcCO2, Transcutaneous partial pressure of carbon dioxide; PetCO2, End-tidal partial pressure of carbon dioxide; NETS, Newborn Emergency Transport Service (Victoria); NICU, Neonatal Intensive Care Unit; PaO2/PAO2 ratio, alveolar-arterial ratio. ADC-FNN Online First, published on April 29, 2005 as 10.1136/adc...

متن کامل

Can Transcutaneous CO2 Tension Be Used to Calculate Ventilatory Dead Space? A Pilot Study

Dead space fraction (V d/V t) measurement performed using volumetric capnography requires arterial blood gas (ABG) sampling to estimate the partial pressure of carbon dioxide (PaCO2). In recent years, transcutaneous capnography (PtcCO2) has emerged as a noninvasive method of estimating PaCO2. We hypothesized that PtcCO2 can be used as a substitute for PaCO2 in the calculation of V d/V t. In thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006