Robotic systems in total hip arthroplasty--is the time ripe for a new approach?

نویسندگان

  • F Mantwill
  • A P Schulz
  • A Faber
  • D Hollstein
  • M Kammal
  • A Fay
  • Ch Jürgens
چکیده

The technical aspects of manual total hip arthroplasty are briefly described. The development, technique and technical problems of previous robotic systems in total hip arthroplasty are described with special details of the Robodoc--System. Recent advances regarding the minimally invasive technique of total-hip implantation and navigation are described. The current development of a robotic assisted system for total hip arthroplasty is presented. This project aims to combine the advantages of minimally invasive techniques and navigational systems with the accuracy that robotic assisted bone milling can provide. The project-name is RomEo (Robotic minimally invasive Endoprosthetics), the main project partners are the Helmut-Schmidt-University/Hamburg and the Department of Trauma and Orthopaedics of the BG Trauma Hospital Hamburg.

منابع مشابه

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Magnetic Resonance Imaging Assessment of Hip Abductor after Total Hip Arthroplasty Using a Direct Lateral Approach

Background: Surgical techniques and rehabilitations after total hip arthroplasty (THA) play a significant role in theimprovement of pain and limping. This study aimed to assess hip abductor muscle’s diameter and its strength after 6months postoperative THA performed by Hardinge approach.Methods: After obtaining the patients’ demographic characteristics, the preoperative values...

متن کامل

Partial 2-Stage Revision in Chronic Hip Arthroplasty Infections: A Review

Background: Periprosthetic hip infections (PHIs) are troublesome complications of hip arthroplasties. The gold standard procedure for treating chronic PHI is a 2-stage approach. Recently, however, more conservative approaches have been developed to spare the osseointegrated components and avoid sequestra, bone loss, devascularization, and difficult reconstructions. The partial ...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • The international journal of medical robotics + computer assisted surgery : MRCAS

دوره 1 4  شماره 

صفحات  -

تاریخ انتشار 2005