A Portable Measurement Instrument for the Measurement of Water Body Chlorophyll-a in the Support of Fluorescence Detection
نویسندگان
چکیده
Chlorophyll-a was regarded as the important indicator to describe the marine primary production because the chlorophyll a content of phytoplankton in the ocean is related to its photosynthesis production.The concentration of chlorophyll a is also the major parameter to evaluate marine water quality, organic pollution and detect the fishing ground, and the temporal and spatial variation of chlorophyll a contains the basic information of sea areas. Based on the spectral characteristics of chlorophyll fluorescence, this document recommends a new dual optical detecting instrument for the measurement of chlorophyll-a concentration , the microcontroller MSP430F149 as the key control module,by controlling the ultra-high brightness LED which wavelength is 450nm to excite chlorophyll a to produce the fluorescent signal about 680nm , at the same time this LED is used as reference light , the dual-optical structure exclude the light fluctuations due to the impact of test results. At last, we get the relationship between relative fluorescence intensity and chlorophyll-a concentration with the spectrophotometer, we find the system has the good linear consistency when measures the low concentrations of chlorophyll-a.
منابع مشابه
An investigation on the possibility of use of chlorophyll fluorescence to study the stomatal behaviour in plants under drought stress
Stomata play a key role in the control of plant water relations and photosynthesis. A rapid non-destructive method to study the stomatal behaviour in aerial parts of plants is important for researchers in plant sciences and agricultural fields. Stomata close in response to drought stress. Stomatal closure causes lower availability of CO2 inside the leaf and thus a decrease in the rate of carbox...
متن کاملMEASUREMENT OF D2O IN WATER USING 2H(?,n)1H REACTION
Utilization of Photodisintegration reaction of Deuterium, 2H(?,n)1H, is a precise technique for determining the percentage of 2H in tritiated and natural water. The 23Na(n,?)24Na reaction is a suitable ?-source for producing the 2H(?,n)1H reaction. Tehran Research Reactor was used as a neutron source for producing 24Na isotopes. The BF3 detectors were used to detect the neutron emission of H2 c...
متن کاملتاثیر تنش شوری بر رنگیزههای فتوسنتزی، فلورسانس و برخی آنتی اکسیدانهای برگ سه رقم بادام زمینی (L. Arachis hypogaea)
To study the effect of salinity on photosynthesis pigments, fluorescence and antioxidants of three varieties of peanut leaf as an indicator of resistance to salinity, research was carried out as factorial arrangement based on completely randomized design with three replications in the greenhouse of University of Guilan in 2013. The experiment consisted of a combination of 4 different salinity l...
متن کاملFLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION
A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...
متن کاملOptimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کامل