Low Flow Liquid Calibration Setup

نویسندگان

  • Tom H. Platenkamp
  • Wouter Sparreboom
  • Gijs H. J. M. Ratering
  • Marcel R. Katerberg
  • Joost C. Lötters
چکیده

This article describes a primary calibration setup, and its uncertainty, for low flow liquid calibrations at Bronkhorst High-Tech. It will be used to calibrate reference flow meters from 1 to 200 g/h. By setting up an uncertainty budget for this setup, the calibration of the instruments can be compared to that of NMI’s (National Metrology Institutes). The uncertainty budget consists of mass, time and mass flow uncertainties/corrections that need to be taken in to account for determining the traceable mass flow. Tests results of different flow meters/actuators measured on the setup support the calculated uncertainty. By participating in an intercomparison with NMI’s the measurement and uncertainty of this setup is traceable to European NMI’s.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Obstacle-based self-calibration techniques for the determination of the permittivity of liquids

In this contribution, different obstacle-based selfcalibration techniques for the measurement of the dielectric properties of liquids are investigated at microwave frequencies. The liquid under test is contained inside a waveguide, which is connected to the ports of a vector network analyzer. The permittivity of the liquid is characterized on the basis of the measured scattering parameters. In ...

متن کامل

Visual Observation of Flow Regime Transition in Downward Vertical Gas-Liquid Flow Using Simple Mixer

Different flow patterns of downward gas-liquid two-phaseflow using simple mixer are studied in an experimental manner. An experimental setup is designed and fabricated to allow the visual observation of downward two-phase flow patterns and their transitions. The flow patterns are recorded by a 1200 frames per second high speed video camera. The quality of downward two-phase flow patterns photos...

متن کامل

Validation of a fully automated robotic setup for preparation of whole blood samples for LC-MS toxicology analysis.

A fully automated setup was developed for preparing whole blood samples using a Tecan Evo workstation. By integrating several add-ons to the robotic platform, the flexible setup was able to prepare samples from sample tubes to a 96-well sample plate ready for injection on liquid chromatography-mass spectrometry using several preparation techniques, including protein precipitation, solid-phase e...

متن کامل

High-resolution continuous-flow analysis setup for water isotopic measurement from ice cores using laser spectroscopy

Here we present an experimental setup for water stable isotope (δO and δD) continuous-flow measurements and provide metrics defining the performance of the setup during a major ice core measurement campaign (Roosevelt Island Climate Evolution; RICE). We also use the metrics to compare alternate systems. Our setup is the first continuousflow laser spectroscopy system that is using off-axis integ...

متن کامل

Flow Measurement and Instrumentation

The Lorentz force flowmeter (LFF) is a measuring device utilizing localized static magnetic fields for the non-contact measurement of the flow rate in electrically conducting fluids. In case of highly aggressive or high-temperature conductive fluids, it is difficult to reproduce in a laboratory the conditions typically met in application. Hence, calibration becomes a difficult task. For the LFF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Micromachines

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2015