Zero expiratory pressure and low oxygen concentration promote heterogeneity of regional ventilation and lung densities

نویسندگان

  • J. B. Borges
  • L. Porra
  • M. Pellegrini
  • A. Tannoia
  • S. Derosa
  • A. Larsson
  • S. Bayat
  • G. Perchiazzi
  • G. Hedenstierna
چکیده

BACKGROUND It is not well known what is the main mechanism causing lung heterogeneity in healthy lungs under mechanical ventilation. We aimed to investigate the mechanisms causing heterogeneity of regional ventilation and parenchymal densities in healthy lungs under anesthesia and mechanical ventilation. METHODS In a small animal model, synchrotron imaging was used to measure lung aeration and regional-specific ventilation (sV̇). Heterogeneity of ventilation was calculated as the coefficient of variation in sV̇ (CVsV̇ ). The coefficient of variation in lung densities (CVD ) was calculated for all lung tissue, and within hyperinflated, normally and poorly aerated areas. Three conditions were studied: zero end-expiratory pressure (ZEEP) and FI O2 0.21; ZEEP and FI O2 1.0; PEEP 12 cmH2 O and FI O2 1.0 (Open Lung-PEEP = OLP). RESULTS The mean tissue density at OLP was lower than ZEEP-1.0 and ZEEP-0.21. There were larger subregions with low sV̇ and poor aeration at ZEEP-0.21 than at OLP: 12.9 ± 9.0 vs. 0.6 ± 0.4% in the non-dependent level, and 17.5 ± 8.2 vs. 0.4 ± 0.1% in the dependent one (P = 0.041). The CVsV̇ of the total imaged lung at PEEP 12 cmH2 O was significantly lower than on ZEEP, regardless of FI O2 , indicating more heterogeneity of ventilation during ZEEP (0.23 ± 0.03 vs. 0.54 ± 0.37, P = 0.049). CVD changed over the different mechanical ventilation settings (P = 0.011); predominantly, CVD increased during ZEEP. The spatial distribution of the CVD calculated for the poorly aerated density category changed with the mechanical ventilation settings, increasing in the dependent level during ZEEP. CONCLUSION ZEEP together with low FI O2 promoted heterogeneity of ventilation and lung tissue densities, fostering a greater amount of airway closure and ventilation inhomogeneities in poorly aerated regions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventilation heterogeneity: small length scales, big challenges.

THE DISTRIBUTION OF REGIONAL ventilation is heterogeneous in normal lung and increases dramatically under pathological conditions. This has been demonstrated both in humans and in animal models using a number of different imaging techniques. General anesthesia and mechanical ventilation can significantly alter the distribution of specific ventilation (sV̇), both through changes in the diaphragma...

متن کامل

Positive End-expiratory Pressure Titration after Alveolar Recruitment Directed by Electrical Impedance Tomography

BACKGROUND Electrical impedance tomography (EIT) is a real-time bedside monitoring tool, which can reflect dynamic regional lung ventilation. The aim of the present study was to monitor regional gas distribution in patients with acute respiratory distress syndrome (ARDS) during positive-end-expiratory pressure (PEEP) titration using EIT. METHODS Eighteen ARDS patients under mechanical ventila...

متن کامل

Application of positive end expiratory pressure during laparoscopic surgery

provided the original work is properly cited. CC Positive-pressure ventilation during general anesthesia is a prerequisite for numerous surgical conditions. Mechanical ventilation is non-physiological and can induce lung injury, although ventilator-induced lung injury may be of minor clinical importance during anesthesia for most patients with healthy lungs. However, growing evidence suggests t...

متن کامل

تأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی

  Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...

متن کامل

Regional ventilation and gas exchange after hemicorporectomy.

Bake, B. and Grimby, G. (1974). Thorax, 29, 366-370. Regional ventilation and gas exchange after hemicorporectomy. Maximum expiratory flow volume curves, gas exchange, closing volume, and regional distribution of lung volumes and ventilation were measured in a young man after hemicorporectomy. The patient breathed at low lung volume, close to residual volume, and his total lung capacity was 63%...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 60  شماره 

صفحات  -

تاریخ انتشار 2016