Material stiffness parameters as potential predictors of presence of left ventricle myocardial infarction: 3D echo-based computational modeling study.
نویسندگان
چکیده
BACKGROUND Ventricle material properties are difficult to obtain under in vivo conditions and are not readily available in the current literature. It is also desirable to have an initial determination if a patient had an infarction based on echo data before more expensive examinations are recommended. A noninvasive echo-based modeling approach and a predictive method were introduced to determine left ventricle material parameters and differentiate patients with recent myocardial infarction (MI) from those without. METHODS Echo data were obtained from 10 patients, 5 with MI (Infarct Group) and 5 without (Non-Infarcted Group). Echo-based patient-specific computational left ventricle (LV) models were constructed to quantify LV material properties. All patients were treated equally in the modeling process without using MI information. Systolic and diastolic material parameter values in the Mooney-Rivlin models were adjusted to match echo volume data. The equivalent Young's modulus (YM) values were obtained for each material stress-strain curve by linear fitting for easy comparison. Predictive logistic regression analysis was used to identify the best parameters for infract prediction. RESULTS The LV end-systole material stiffness (ES-YMf) was the best single predictor among the 12 individual parameters with an area under the receiver operating characteristic (ROC) curve of 0.9841. LV wall thickness (WT), material stiffness in fiber direction at end-systole (ES-YMf) and material stiffness variation (∆YMf) had positive correlations with LV ejection fraction with correlation coefficients r = 0.8125, 0.9495 and 0.9619, respectively. The best combination of parameters WT + ∆YMf was the best over-all predictor with an area under the ROC curve of 0.9951. CONCLUSION Computational modeling and material stiffness parameters may be used as a potential tool to suggest if a patient had infarction based on echo data. Large-scale clinical studies are needed to validate these preliminary findings.
منابع مشابه
Address for correspondence
Material and methods. The study involved 301 patients on HD (n = 301) and PD (n = 58), who were divided into subgroups according to DV. The subjects’ medical histories included diabetes mellitus (DM), myocardial infarction (MI), stroke, CV deaths and deaths from non-CV causes. Their CV parameters were measured with ECHO for the left ventricle ejection fraction (EF), posterior wall (LVW) and int...
متن کاملDetection of Left Ventricular Remodeling in Acute ST Elevation Myocardial Infarction after Primary Percutaneous Coronary Intervention by Two Dimensional and Three Dimensional Echocardiography
Background Left ventricular remodeling (LVR) after ST-elevation myocardial infarction (STEMI) harbingers poor prognosis. Three-dimensional echocardiography (3DE) is more accurate than 2 D echo for the assessment of left ventricle (LV) shape. We assessed LV geometry with 3D ECHO 6 months after STEMI in patients who had primary angioplasty. Materials and Methods In this prospective study, morph...
متن کامل3D Echo Pilot Study of Geometric Left Ventricular Changes after Acute Myocardial Infarction
BACKGROUND Left ventricular remodeling (LVR) after AMI characterizes a factor of poor prognosis. There is little information in the literature on the LVR analyzed with three-dimensional echocardiography (3D ECHO). OBJECTIVE To analyze, with 3D ECHO, the geometric and volumetric modifications of the left ventricle (VE) six months after AMI in patients subjected to percutaneous primary treatmen...
متن کاملMyocardial damage of the entire ventricular region in a patient with acute myocardial infarction
Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...
متن کاملClinical Significance of P Wave Dispersion in Prediction of Atrial Fibrillation in Patients with Acute Myocardial Infarction
Background: P wave dispersion (PWD) is defined as the difference between the maximum P wave duration (Pmax) and the minimum P wave duration (Pmin) in 12-leads of the surface electrocardiography. The aim of this study was to evaluate the values of PWD during atrial fibrillation (AF) after acute myocardial infarction (AMI). Methods: We prospectively evaluated atrial rhythms of 350 patients (251 m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical engineering online
دوره 15 شماره
صفحات -
تاریخ انتشار 2016