Perspectives on resorbable osteosynthesis materials in craniomaxillofacial surgery.

نویسندگان

  • Paul Schumann
  • Daniel Lindhorst
  • Maximilian E H Wagner
  • Alexander Schramm
  • Nils-Claudius Gellrich
  • Martin Rücker
چکیده

Since introduction to the clinics in the 1990s, resorbable osteosynthesis systems have undergone extensive improvements in order to establish their use as a standard treatment, especially in craniomaxillofacial surgery. However, the development of osteosynthesis systems made of poly(α-hydroxy acid) polymers has been hindered by the lack of information on the mechanical properties and biocompatibility of these materials. Moreover, magnesium-based degredable osteosynthesis materials have not yet been integrated into clinical practice owing to biocompatibility problems. Osteosynthesis systems made from nonresorbable titanium alloys have shown excellent biocompatibility, stability and individual fitting to the implant bed, so these materials are currently considered the 'gold standard'. The procedure of plate removal has been subjected to intense scrutiny and controversy. Bioresorbable materials are indicated for special conditions, such as osteosynthesis of the growing skull or orbital floor reconstructions. This paper presents an overview of the currently available and investigated resorbable osteosynthesis materials in comparison with the nonresorbable 'gold standard' titanium. The main problem areas such as sterilization, biocompatibility and stability are highlighted and perspectives for further improvements are provided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro resistance of titanium and resorbable (poly L-co-DL lactic acid) osteosynthesis in mandibular body fracture.

This study was a comparative evaluation of the bending resistance of metallic and resorbable plates and screws in a mandibular body fracture model. Forty polyurethane synthetic hemimandibles were used; a vertical linear cut was made between the second and first premolars. These 40 hemimandibles were divided into four groups of 10 and were fixed with titanium plates and screws or resorbable plat...

متن کامل

Prospective assessment of complications associated with ultrasound activated resorbable pin osteosynthesis in pediatric craniofacial surgery: preliminary results.

Ultrasound activated resorbable pin osteosynthesis (UARPO) has recently shown favourable results in operations on children suffering for craniosynostosis. However, data on complications coming with this new technique in children suffering from craniosynostoses are scarce and have only been assessed retrospectively so far. It has been the aim of the present study to prospectively follow up child...

متن کامل

Resorbable osteosynthesis material – using SonicWeld system

material is to avoid a second operation to remove the plates and screws. Additional surgery has inherent risks and further social, health political and economic burden can be avoided . There have been frequent discussions about leaving metallic osteosynthesis material in situ and this option is seen in the various regional and national differences. Despite the body’s tolerance of titanium, remo...

متن کامل

تعیین مناسب ترین الگوی توزیع تنش (به روش اجزا محدود) در روش‌های ثابت نمودن با پیچ قابل جذب پس از جراحی ساژیتال دو طرفه راموس

Background and Aim: Due to the complications associated with fixation by Titanium screws and plates in Bilateral Sagittal Split Ramus Osteotomy (BSSRO) surgery, the use of resorbable polymers has been increasingly recommended. Since there are not enough studies on this issue, this study aimed to assess the most appropriate stress distribution in fixation with resorbable screws after BSSRO surge...

متن کامل

Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact

OBJECTIVES Screw fixation and fragment anchoring in osteoporotic bones is often difficult. Problems like the cut out phenomenon and implant migration in osteoporotic bones have been reported. One possibility of improving the anchoring force of screws is augmentation of the screw. Cement-augmented screws in spinal surgery could exhibit a better anchoring in osteoporotic bones. METHODS The purp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pathobiology : journal of immunopathology, molecular and cellular biology

دوره 80 4  شماره 

صفحات  -

تاریخ انتشار 2013