Modeling rectangular cantilevers during torsion and deflection for application to frictional force microscopy.
نویسندگان
چکیده
A numerical and experimental analysis of the optical beam deflection system used to monitor microcantilevers subjected to simultaneous deflection and twisting such as in lateral or frictional force microscopy was performed. This study focused on two optical beam deflection orientations where in the first case the optical beam and the detector are at a right angle to the length of the cantilever and the second case, which is the more standard orientation, the optical beam is parallel to the length of the lever. This study finds that it is possible to model the twist and the deflection separately and treat each motion independently. Simulations have shown that the above-mentioned systems are equivalent in accuracy and sensitivity for monitoring the simultaneous twist and deflection of cantilevers.
منابع مشابه
Calibration of frictional forces in atomic force microscopy
The atomic force microscope can provide information on the atomic-level frictional properties of surfaces, but reproducible quantitative measurements are difficult to obtain. Parameters that are either unknown or difficult to precisely measure include the normal and lateral cantilever force constants (particularly with microfabricated cantilevers), the tip height, the deflection sensor response...
متن کاملBuckling of multi wall carbon nanotube cantilevers in the vicinity of graphite sheets using monotone positive method
In this paper, a monotone positive solution is studied for buckling of a distributed model of multi walled carbon nanotube (MWCNT) cantilevers in the vicinity of thin and thick graphite sheets subject to intermolecular forces. In the modeling of intermolecular forces, Van der Waals forces are taken into account. A hybrid nano-scale continuum model based on Lennard–Jones potential is applied to ...
متن کاملSensitivity Analysis of Frequency Response of Atomic Force Microscopy in Liquid Environment on Cantilever's Geometrical Parameters
In this paper, the non-linear dynamic response of rectangular atomic force microscopy in tapping mode is considered. The effect of cantilever’s geometrical parameters (e.g., cantilever length, width, thickness, tip length and the angle between the cantilever and the sample's surface in liquid environment has been studied by taking into account the interaction forces. Results indicate that the r...
متن کاملReal-time deflection and friction force imaging by bimorph-based resonance-type high-speed scanning force microscopy in the contact mode
UNLABELLED We report herein an alternative high-speed scanning force microscopy method in the contact mode based on a resonance-type piezoelectric bimorph scanner. The experimental setup, the modified optical beam deflection scheme suitable for smaller cantilevers, and a high-speed control program for simultaneous data capture are described in detail. The feature of the method is that the defle...
متن کاملImproved atomic force microscopy cantilever performance by partial reflective coating
Optical beam deflection systems are widely used in cantilever based atomic force microscopy (AFM). Most commercial cantilevers have a reflective metal coating on the detector side to increase the reflectivity in order to achieve a high signal on the photodiode. Although the reflective coating is usually much thinner than the cantilever, it can still significantly contribute to the damping of th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada
دوره 15 3 شماره
صفحات -