Joule-thomson Cooling Due to Co2 Injection into Natural Gas Reservoirs
نویسنده
چکیده
Depleted natural gas reservoirs are a promising target for Carbon Sequestration with Enhanced Gas Recovery (CSEGR). The focus of this study is on evaluating the importance of Joule-Thomson cooling during CO2 injection into depleted natural gas reservoirs. Joule-Thomson cooling is the adiabatic cooling that accompanies the expansion of a real gas. If Joule-Thomson cooling were extreme, injectivity and formation permeability could be altered by the freezing of residual water, formation of hydrates, and fracturing due to thermal stresses. The TOUGH2/EOS7C module for CO2-CH4-H2O mixtures is used as the simulation analysis tool. For verification of EOS7C, the classic Joule-Thomson expansion experiment is modeled for pure CO2 resulting in Joule-Thomson coefficients in agreement with standard references to within 5-7%. For demonstration purposes, CO2 injection at constant pressure and with a large pressure drop (~50 bars) is presented in order to show that cooling by more than 20 C can occur by this effect. Two more-realistic constant-rate injection cases show that for typical systems in the Sacramento Valley, California, the Joule-Thomson cooling effect is minimal. This simulation study shows that for constant-rate injections into high-permeability reservoirs, the Joule-Thomson cooling effect is not expected to create significant problems for CSEGR.
منابع مشابه
Developing a Novel Temperature Model in Gas Lifted Wells to Enhance the Gas Lift Design
In the continuous gas lift operation, compressed gas is injected into the lower section of tubing through annulus. The produced liquid flow rate is a function of gas injection rate and injection depth. All the equations to determine depth of injection assumes constant density for gas based on an average temperature of surface and bottomhole that decreases the accuracy of gas lift design. Also g...
متن کاملTransient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation
Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...
متن کاملWellbore associated problems due to gas injection into non-horizontal structures
The rapid growth in natural gas consumption has increased the need for gas storage, in particular in the form of injection into depleted reservoirs. Also, CO2 sequestration into the depleted reservoirs has attracted a large attention recently. However, it is important to ensure that the injection pressure is maintained below a certain limit to avoid unsealing the cap rock or reactivation of any...
متن کاملHow to Design a Cryogenic Joule-Thomson Cooling System: Case Study of Small Hydrogen Liquefier
Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...
متن کاملTechno-Economic and Environmental Evaluation of Expansion Turbines for Gas Field Improvement (Case study)
Regarding the increased energy consumption of the processes at the operational units in the National Iranian Oil Company, the present study analyzed energy consumption at one of the gas refineries. In this refinery, which is the main supplier of Fajr Jam refinery for the national gas network, as well as an injection into the oil fields of the Iranian South oil company, the pressure of gas after...
متن کامل