Comparison Between the Accuracy of NovApex Apex Locator and Radiographs in Determining Radiographic Apex

نویسندگان

  • Shahriar Shahi
  • Saeed Rahimi
  • Amin Salem Milani
  • Mohammad Asghari Jafarabadi
  • Gholam Reza Djoorabbaf Naghsh
چکیده

INTRODUCTION Determination of the canal working length with radiographs has many drawbacks. Electronic apex locators have been developed to overcome some of these problems. Recently, a newly designed apex locator called NovApex has been introduced. All the studies conducted to determine the accuracy of NovApex have been carried out in-vitro on extracted teeth. The aim of this in vivo study was to evaluate the accuracy of NovApex compared with traditional radiographic method. MATERIALS AND METHODS Twenty-five patients whose lower molars that were candidates for extraction were selected. The teeth were accessed, and the radiographic working length was determined by measuring the length of the initial file 0.5mm short of the radiographic apex. Then, NovApex apex locator was used to measure the electronic working length. Subsequently, the tooth was extracted, and the actual working length was measured by introducing a size #15 K-file into each canal until the file tip was visible at the apex, then 1.5mm was subtracted to attain the working length. Cohen's Kappa was computed for each of the methods versus actual working length as a measure of reliability. The accuracies were compared using Chi-square test. RESULTS The accuracy of NovApex apex locator and radiographic method in detecting the apical end point within ±0.5mm was 74.7% and 68%, respectively; this was not significantly different (P<0.001). CONCLUSION The NovApex apex locator is useful in detecting the apical end point with the accuracy similar to radiographic method. However, neither technique is fully reliable in detecting the apical end point of the canal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

متن کامل

مقایسه دقت دستگاه‌های اپکس یاب الکترونیکی ZX Root،Novapex  در مقایسه با رادیوگرافی در شرایط in vivo

Background and Aims: Working length determination and remaining this length is of great importance in root canal therapy. Recently, electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the sensitivity of Root ZX and Novapex electronic apex locators with radiography in a clinical study. Materials and...

متن کامل

Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study.

INTRODUCTION This ex vivo study evaluated the accuracy of the Root-ZX electronic apex locator (EAL) (J. Morita, Tokyo, Japan) and the NovApex (Forum Technologies, Rishon Lezion, Israel) in determining the working length (WL) during endodontic treatment. MATERIALS AND METHODS Forty extracted single-rooted human teeth were selected for this study. The actual WL was measured with visual techniqu...

متن کامل

Influence of pulp condition on the accuracy of an electronic foramen locator in posterior teeth: an in vivo study.

The aim of this study was to assess, in vivo, the accuracy of the NovApex® electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex®was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex® locator and confirmed using the radiographic method. Differences be...

متن کامل

Accuracy of Different Methods of Working Length Determination in Endodontics

Background: Accurate assessment of the working length determines the success and prognosis of endodontic treatment. There are no systematic reviews comparing the accuracy of different methods of working length determination in endodontics Aim: To evaluate clinical studies on the accuracy of different methods used for working length determination in endodontics. Search strategy: Search was condu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011