Rf Pulse Design Methods for Reduction of Image Artifacts in Parallel Rf Excitation: Comparison of 3 Techniques on a 3t Parallel Excitation System with 8 Channels

نویسندگان

  • A. C. Zelinski
  • L. L. Wald
  • K. Setsompop
  • V. Alagappan
  • B. A. Gagoski
  • F. Hebrank
چکیده

A. C. Zelinski, L. L. Wald, K. Setsompop, V. Alagappan, B. A. Gagoski, F. Hebrank, U. Fontius, F. Schmitt, and E. Adalsteinsson Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, United States, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA, United States, Siemens Medical Solutions, Erlangen, Germany

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RF Pulse Design for Parallel Excitation

1. Introduction Parallel excitation has been introduced as a means of accelerating multi-dimensional, spatially-selective excitation using multiple transmit coils, each driven by a unique RF pulse (1,2). In a manner analogous to parallel imaging, parallel excitation allows the use of a reduced excitation k-space trajectory (7) to achieve a desired excitation pattern, by exploiting the blurring ...

متن کامل

Minimal-SAR RF Pulse Optimization in Parallel Transmission

INTRODUCTION Parallel transmission is an emerging technique that has great potential in many applications such as reducing selective RF pulse duration and improving B1 and B0 field inhomogeneity in high fields [1-3]. A potential issue in parallel transmission is elevated RF power deposition which is characterized by the specific absorption ratio (SAR). In parallel excitation, the effect of elec...

متن کامل

Comparison of Three Algorithms for Solving Linearized Systems of Parallel Excitation RF Waveform Design Equations: Experiments on an Eight-Channel System at 3 Tesla

Three algorithms for solving linearized systems of RF waveform design equations for calculating accelerated spatially-tailored excitations on parallel excitation MRI systems are presented. Their artifact levels, computational speed, and RF peak and root-mean-square (RMS) voltages are analyzed. An SVD-based inversion method is compared with conjugate gradient least squares (CGLS) and least squar...

متن کامل

Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Parallel transmitter techniques are a promising approach for reducing transmitter B1 inhomogeneity due to the potential for adjusting the spatial excitation profile with independent RF pulses. These techniques may be further improved with transmit sensitivity encoding (SENSE) methods because the sensitivity information in pulse design provides an excitation that is inherently compensated for tr...

متن کامل

A Minimum SAR RF Pulse Design Approach for Parallel Tx with Local Hot Spot Suppression and Exact Fidelity Constraint

Introduction With increasing field-strength, the local specific absorption rate (SAR) becomes a limiting factor for MR imaging applications. However, using parallel Tx systems, it becomes possible to tailor the E-fields in the RF pulse design. Certain SAR optimal algorithms have been proposed, e.g. [1], that constrain a specific local region for SAR (e.g., the eyes). This is in general insuffic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007