چکیده

BACKGROUND Magnetic Resonance (MR) diffusion tensor imaging (DTI) is able to quantify in vivo tissue microstructure properties and to detect disease related pathology of the central nervous system. Nevertheless, DTI is limited by low spatial resolution associated with its low signal-to-noise-ratio (SNR). AIM The aim is to select a DTI sequence for brain clinical studies, optimizing SNR and resolution. METHODS AND RESULTS We applied 6 methods for SNR computation in 26 DTI sequences with different parameters using 4 healthy volunteers (HV). We choosed two DTI sequences for their high SNR, they differed by voxel size and b-value. Subsequently, the two selected sequences were acquired from 30 multiple sclerosis (MS) patients with different disability and lesion load and 18 age matched HV. We observed high concordance between mean diffusivity (MD) and fractional anysotropy (FA), nonetheless the DTI sequence with smaller voxel size displayed a better correlation with disease progression, despite a slightly lower SNR. The reliability of corpus callosum (CC) fiber tracking with the chosen DTI sequences was also tested. CONCLUSIONS The sensitivity of DTI-derived indices to MS-related tissue abnormalities indicates that the optimized sequence may be a powerful tool in studies aimed at monitoring the disease course and severity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cranial nerve tractography with 3T PROPELLER Diffusion Tensor Imaging

[Introduction] Cranial nerves are small nerves that control various sensory and/or motor functions and these nerves emerge from the brainstem. Conventional anatomical scan such as T1/T2 weighed MRI is commonly used to identify these nerves, but sometimes it is difficult to track the pathways due to complex structure. To visualize complex fiber structure, Diffusion Tensor Imaging (DTI) has been ...

متن کامل

Anisotropic Anomalous Filter as a Tool for Decreasing Patient Exam Time in Diffusion Weighted Mri Protocols

Diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) are noisy submodalities images in magnetic resonance imaging (MRI) and usually have long acquisition time due to repetitions needed to improve the signal noise ratio (SNR). Here we propose and evaluate anisotropic anomalous diffusion (AAD) filter on DTI and DWI to enhance SNR and reduce the need for repetitions. Anisotropic ano...

متن کامل

Feasibility of Diffusion Tensor Imaging at 1.5T Using Multi-Band Echo Planar Acquisition

We report that diffusion tensor imaging (DTI) and tractography (DTT) of the pyramidal tracts using multi-band (MB) EPI could be a useful tool with a 1.5T MRI. We compared images using single-band EPI (SB-EPI) and MB-EPI. MB-EPI could reduce the scanning time by about 40%. We demonstrated that it is comparable between image qualities of SB-EPI and MB-EPI using tract-specific analysis and dice co...

متن کامل

Emergency department resource optimisation for improved performance: a review

Emergency departments (EDs) have been becoming increasingly congested due to the combined impacts of growing demand, access block and increased clinical capability of the EDs. This congestion has known to have adverse impacts on the performance of the healthcare services. Attempts to overcome with this challenge have focussed largely on the demand management and the application of system wide p...

متن کامل

High b-value Acquisition using CURVE-ball DTI

Overview: The characteristics of water diffusion parallel and perpendicular to white matter tracts are a sensitive indicator of tissue microstructure and cannot be fully determined from single b-value DTI. In order to obtain singleor two-tensor DTI data with multiple b-values and acceptable SNR in clinically reasonable times, a new data acquisition strategy is proposed – CURVE-ball DTI (CUbe Ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2010  شماره 

صفحات  -

تاریخ انتشار 2010