Antimicrobial activity of a novel catheter lock solution.
نویسندگان
چکیده
Intravascular catheter-associated bloodstream infections significantly increase rates of morbidity and hospital costs. Microbial colonization and development of biofilms, which are known to be recalcitrant to antibiotic therapy, often lead to the loss of otherwise patent vascular access systems. We evaluated a new taurolidine- and citrate-based catheter lock solution (Neutrolin; Biolink Corporation, Norwell, Mass.) for its activity against planktonic microbes, antimicrobial activity in a catheter model, and biofilm eradication activity. In studies of planktonic microbes, after 24 h of contact, 675 mg of taurolidine-citrate solution per liter caused > 99% reductions in the initial counts of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and Entercoccus faecalis. A solution of 13,500 mg/liter was cidal for Candida albicans. Ports and attached catheters inoculated with 50 to 600 CFU of these bloodstream isolates per ml were locked with heparin or the taurolidine-citrate solution. After 72 h, there was no growth in the taurolidine-citrate-treated devices but the heparin-treated devices exhibited growth in the range of 6 x 10(2) to 5 x 10(6) CFU/ml. Biofilms were developed on silicone disks in modified Robbins devices with broth containing 6% serum (initial counts, 10(6) to 10(8) CFU/cm(2)). The axenic biofilms were treated for 24 h with taurolidine-citrate or heparin. Taurolidine-citrate exposure resulted in a median reduction of 4.8 logs, whereas heparin treatment resulted in a median reduction of 1.7 logs (P < 0.01). No significant differences in the effects of the two treatments against P. aeruginosa and C. albicans were observed. These findings suggest that taurolidine-citrate is a promising combination agent for the prevention and treatment of intravascular catheter-related infections.
منابع مشابه
Comparison of ML8-X10 (a prototype oil-in-water micro-emulsion based on a novel free fatty acid), taurolidine/citrate/heparin and vancomycin/heparin antimicrobial lock solutions in the eradication of biofilm-producing staphylococci from central venous catheters.
OBJECTIVES Antimicrobial lock solutions are used for prevention and management of catheter-related bloodstream infections. ML8-X10 (a prototype oil-in-water micro-emulsion based on a novel free fatty acid), vancomycin/heparin and taurolidine/citrate/heparin (Taurolock™-Hep500) lock solutions were tested against biofilm-forming Staphylococcus epidermidis and methicillin-susceptible Staphylococcu...
متن کاملA novel antimicrobial and antithrombotic lock solution for hemodialysis catheters: a multi-center, controlled, randomized trial.
BACKGROUND AND PURPOSE Catheter-related bloodstream infection is the greatest threat to the safety of patients on hemodialysis. Catheter lock solutions containing heparin have been linked to an increased risk of hemorrhage and thrombocytopenia. OBJECTIVES To ascertain the safety and efficacy for prevention of catheter-related bloodstream infection and catheter loss from patency failure of a n...
متن کاملIs Taurolidine-citrate an effective and cost-effective hemodialysis cathe-ter lock solution? A systematic review and cost- effectiveness analysis
Background: Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other ...
متن کاملIntravascular catheter-related infections: advances in diagnosis, prevention, and management.
Indwelling vascular catheters are a leading source of bloodstream infections in critically ill patients and cancer patients. Because clinical diagnostic criteria are either insensitive or non-specific, such infections are often overdiagnosed, resulting in unnecessary and wasteful removal of the catheter. Catheter-sparing diagnostic methods, such as differential quantitative blood cultures and t...
متن کاملOptimal antimicrobial catheter lock solution, using different combinations of minocycline, EDTA, and 25-percent ethanol, rapidly eradicates organisms embedded in biofilm.
Antimicrobial lock solutions may be needed to salvage indwelling catheters in patients requiring continuous intravenous therapy. We determined the activity of minocycline, EDTA, and 25% ethanol, alone or in combination, against methicillin-resistant Staphylococcus aureus and Candida parapsilosis catheter-related bloodstream infection strains in two established models of biofilm colonization. Bi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 46 6 شماره
صفحات -
تاریخ انتشار 2002