Keratoprosthesis: preoperative prognostic categories.
نویسندگان
چکیده
PURPOSE Recent advances aimed at preventing and treating complications after keratoprosthesis surgery have improved prognosis, but it has been suspected that various preoperative diagnoses may carry substantially different postoperative outcomes. This article attempts to clarify the ranking of prognostic categories for patients undergoing keratoprosthesis surgery. METHODS A retrospective review of the outcome in a recent series of 63 patient eyes operated at the Massachusetts Eye and Ear Infirmary between 1990 and 1997 and followed up for a minimum of 21 months. Anatomic retention of the device and the loss of vision caused by complications were recorded. The patients were divided into four categories according to preoperative cause. RESULTS Anatomically, one keratoprosthesis extruded spontaneously. Another 10 were permanently removed because of complications. Of the 63 eyes, 10 never achieved a visual acuity of at least 20/200 vision because of preexisting retinal or optic nerve damage. The remaining 53 had a visual acuity of 20/200 to 20/20 as follows: Stevens-Johnson syndrome (n = 7), after 2 years: 33%, after 5 years: 0%; chemical burn (n = 17), after 2 years: 64%, after 5 years: 25%; ocular cicatricial pemphigoid (n = 20), after 2 years: 72%, after 5 years: 43%; graft failure in noncicatrizing conditions (dystrophies, degenerations, or bacterial or viral infections) when a repeat graft was expected to have a poor prognosis (n = 19), after 2 years: 83%, after 5 years: 68%. The difference in outcome between the Stevens-Johnson syndrome outcome group and the graft failure group or the ocular cicatricial pemphigoid group was statistically significant. In the group of 53 eyes, visual acuity was restored to 20/200 to 20/20 for a cumulative total of 138 years. CONCLUSION Outcome of the keratoprosthesis surgery varied markedly with preoperative diagnosis. Most favorable was graft failures in non-cicatrizing conditions, whereas Stevens-Johnson syndrome was the worst. Ocular cicatricial pemphigoid and chemical burns occupied a middle ground. The difference between the groups seemed to correlate with the degree of past preoperative inflammation.
منابع مشابه
Boston type 1 keratoprosthesis: the university of california davis experience.
PURPOSE To compare the University of California Davis experience using the Boston keratoprosthesis with the Boston Keratoprosthesis Study Group's initial report. DESIGN Retrospective chart review. PARTICIPANTS We analyzed 30 eyes of 28 patients who previously underwent Boston type 1 keratoprosthesis surgery at our institution between 2004 and 2008. METHODS Preoperative, intraoperative, an...
متن کاملResults from the multicenter Boston Type 1 Keratoprosthesis Study.
PURPOSE To report indications, practices, complications, and outcomes from the first multicenter study on the Boston Type 1 keratoprosthesis. DESIGN Prospective, noncomparative, interventional case series. PARTICIPANTS We analyzed 141 Boston Type 1 keratoprosthesis surgical procedures, from 17 surgical sites, done from January 2003 through September 2005 in 136 eyes of 133 patients. METHO...
متن کاملUltra High Resolution Optical Coherence Tomography in Boston Type I Keratoprosthesis
PURPOSE To evaluate the anterior keratoprosthesis-cornea interface in eyes with Boston type I keratoprosthesis (Kpro). METHODS In a prospective non-interventional study, patients with Boston type I Kpro underwent ultra-high resolution optical coherence tomography (UHR-OCT) evaluation. The images were used to measure and describe characteristics of the anterior keratoprosthesis-cornea interfac...
متن کاملBoston type 1 keratoprosthesis from patient selection through postoperative management: a review for the keratoprosthetic surgeon
For the anterior segment surgeon, the implantation of Boston type 1 keratoprosthesis is a multistep process that begins with careful patient selection. Success depends on thorough preoperative evaluation, detailed surgical planning, and frequent postoperative follow-up. New practice patterns have emerged for each of these phases as the international experience with keratoprosthesis grows. This ...
متن کاملFive year follow up of biocolonisable microporous fluorocarbon haptic (BIOKOP) keratoprosthesis implantation in patients with high risk of corneal graft failure.
AIM To study the anatomical and visual performance following implantation of a model of artificial cornea and to evaluate the postoperative long term complications. METHODS 11 eyes of 11 patients with bilateral corneal blindness considered as potentially having high risk of failure of penetrating corneal keratoplasty were implanted with biocolonisable Kpro keratoprosthesis (BIOKOP I, FCI, Ran...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cornea
دوره 20 1 شماره
صفحات -
تاریخ انتشار 2001