Navigator-Free Dynamic Phase Correction for Echo-Planar Imaging Based Functional MRI

نویسندگان

  • D. Xu
  • R. S. Hinks
  • B. D. Collick
چکیده

INTRODUCTION In dynamic echo-planar imaging (EPI), such as functional MRI, where a time series of EPI images are collected, there is additional modulation along echo readout due to changes in hardware states (e.g., temperature) that the standard reference scan based phase correction methods [1-3] cannot account for, thereby resulting in an increase of ghost level over time. To address this problem, non-phase-encoded navigator echoes can be collected at each temporal frame to calibrate the additional modulation between odd and even echoes [4]. The per-temporal-frame modulation is then corrected in image reconstruction in addition to the static modulation measured from the reference scan. However, the navigator-based method assumes that the additional modulation that the center echoes (corresponding to echoes covering the center of the k-space) experience is the same as that predicted by the first few navigator echoes. When this assumption is not true (e.g., when there is additional modulation building up across the echo train), the modulation of the center echoes would not be well corrected, thereby still leading to significant ghost drift. We propose a new, navigator-free method to use scan data itself for estimating the additional per-temporal-frame modulation. This method can estimate the modulation more faithfully than the navigator-based method, thus significantly reduced ghost drift.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging.

In functional magnetic resonance imaging, a rapid method such as echo-planar (EPI) or spiral is used to collect a dynamic series of images. These techniques are sensitive to changes in resonance frequency which can arise from respiration and are more significant at high magnetic fields. To decrease the noise from respiration-induced phase and frequency fluctuations, a simple correction of the "...

متن کامل

Interleaved multishot imaging by spatiotemporal encoding: A fast, self-referenced method for high-definition diffusion and functional MRI.

PURPOSE Single-shot imaging by spatiotemporal encoding (SPEN) can provide higher immunity to artifacts than its echo planar imaging-based counterparts. Further improvements in resolution and signal-to-noise ratio could be made by rescinding the sequence's single-scan nature. To explore this option, an interleaved SPEN version was developed that was capable of delivering optimized images due to ...

متن کامل

High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition.

Single-shot echo-planar imaging (EPI) is well established as the method of choice for clinical, diffusion-weighted imaging with MRI because of its low sensitivity to the motion-induced phase errors that occur during diffusion sensitization of the MR signal. However, the method is prone to artifacts due to susceptibility changes at tissue interfaces and has a limited spatial resolution. The intr...

متن کامل

Correcting dynamic distortions in 7T echo planar imaging using a jittered echo time sequence

PURPOSE To develop a distortion correction method for echo planar imaging (EPI) that is able to measure dynamic changes in B0 . THEORY AND METHODS The approach we propose is based on single-echo EPI with a jittering of the echo time between two values for alternate time points. Field maps are calculated between phase images from adjacent volumes and are used to remove distortion from correspo...

متن کامل

High-resolution diffusion MRI at 7T using a three-dimensional multi-slab acquisition

High-resolution diffusion MRI can provide the ability to resolve small brain structures, enabling investigations of detailed white matter architecture. A major challenge for in vivo high-resolution diffusion MRI is the low signal-to-noise ratio. In this work, we combine two highly compatible methods, ultra-high field and three-dimensional multi-slab acquisition to improve the SNR of high-resolu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009