Three-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing.
نویسندگان
چکیده
AIMS The accuracy of transcatheter aortic valve replacement (TAVR) sizing using three-dimensional transoesophageal echocardiography (3D-TEE) compared with the gold-standard multi-slice computed tomography (MSCT) remains unclear. We compare aortic annulus measurements assessed using these two imaging modalities. METHODS AND RESULTS We performed a single-centre prospective cohort study, including 53 consecutive patients undergoing TAVR, who had both MSCT and 3D-TEE for aortic annulus sizing. Aortic annular dimensions, expected transcatheter heart valve (THV) oversizing, and hypothetical valve size selection based on CT and TEE were compared. 3D-TEE and CT cross-sectional mean diameter (r = 0.69), perimeter (r = 0.70), and area (r = 0.67) were moderately to highly correlated (all P-values <0.0001). 3D-TEE-derived measurements were significantly smaller compared with MSCT: perimeter (68.6 ± 5.9 vs. 75.1 ± 5.7 mm, respectively; P < 0.0001); area (345.6 ± 64.5 vs. 426.9 ± 68.9 mm(2), respectively; P < 0.0001). The percentage difference between 3D-TEE and MSCT measurements was around 9%. Agreement between MSCT- and 3D-TEE-based THV sizing (perimeter) occurred in 44% of patients. Using the 3D-TEE perimeter annular measurements, up to 50% of patients would have received an inappropriate valve size according to manufacturer-recommended, area-derived sizing algorithms. CONCLUSION Aortic annulus measurements for pre-procedural TAVR assessment by 3D-TEE are significantly smaller than MSCT. In this study, such discrepancy would have resulted in up to 50% of all patients receiving the wrong THV size. 3D-TEE should be used for TAVR sizing, only when MSCT is not available or contraindicated. The clinical impact of this information requires further study.
منابع مشابه
FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.
can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...
متن کاملAortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.
OBJECTIVES This study compared cross-sectional three-dimensional (3D) transesophageal echocardiography (TEE) to two-dimensional (2D) TEE as methods for predicting aortic regurgitation after transcatheter aortic valve replacement (TAVR). BACKGROUND Data have shown that TAVR sizing using cross-sectional contrast computed tomography (CT) parameters is superior to 2D-TEE for the prediction of par...
متن کاملMultimodality Imaging in Transcatheter Mitral Interventions
Both echocardiography (specifically transesophageal echocardiography [TEE]) and multidetector row computed tomography (MDCT) have played an integral role in preprocedural planning for transcatheter aortic valve replacement, heavily influencing the moniker of “multimodality imaging.” The strengths of each modalities are complementary (Table), although there is overlap between the preprocedural a...
متن کاملPreparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.
OBJECTIVES This study sought to evaluate whether supra-aortic angiography during preparatory balloon aortic valvuloplasty (BAV) improves valve sizing. BACKGROUND Current recommendations for valve size selection are based on annular measurements by transesophageal echocardiography and computed tomography, but paravalvular aortic regurgitation (PAR) is a frequent problem. METHODS Data of 270 ...
متن کاملAortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing.
OBJECTIVES The precise sizing of the aortic annulus is crucial in order to select the most appropriate valve size for transcatheter aortic valve implantation (TAVI). Owing to the closed heart situation in TAVI, sizing has to be performed based on preoperative imaging when compared with direct sizing during conventional procedures. The aim of the study was to evaluate valve sizing performed eith...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2016