Modeling and Control for Cooling Management of Data Centers with Hot Aisle Containment
نویسندگان
چکیده
In traditional raised-floor data center design with hot aisle and cold aisle separation, the cooling efficiency suffers from recirculation resulting from the mixing of cool air from the Computer Room Air Conditioning (CRAC) units and the hot exhaust air exiting from the back of the server racks. To minimize recirculation and hence increase cooling efficiency, hot aisle containment has been employed in an increasing number of data centers. Based on the underlying heat transfer principles, we present in this paper a dynamic model for cooling management in both open and contained environment, and propose decentralized model predictive controllers (MPC) for control of the CRAC units. One approach to partition a data center into overlapping CRAC zones of influence is discussed. Within each zone, the CRAC unit blower speed and supply air temperature are adjusted by a MPC controller to regulate the rack inlet temperatures, while minimizing the cooling power consumption. The proposed decentralized cooling control approach is validated in a production data center with hot aisles contained by plastic strips. Experimental results demonstrate both its stability and ability to reject various disturbances.
منابع مشابه
Analyzing the Cooling Efficiency of the Thermal Environment in Data Centers
Given the explosive growth of data, scalability and fault tolerance have become a fundamental challenge for data center network structures. Temperature in data centers significantly affects the failure ratio of high-speed network devices. Various types of air distribution schemes influence the temperature of network equipment differently, and the cooling cost in data centers dominates the overa...
متن کاملControl of Server Inlet Temperatures in Datacenters- A Long Overdue Strategy
One of the most critical parameters in the operation of a data center is the inlet temperature of the servers. The ability to control these temperatures is essential for the effective performance of any data center. In this paper we demonstrate why control is important, how it can be achieved, and also present a comparison of the currently available data center cooling technologies, along with ...
متن کاملCfd Simulations Comparing Hard Floor and Raised Floor Configurations in an Air Cooled Data Center
An increasing number of companies and organisations have started to outsource their data storage. Although the potential of future investments in data centers is prosperous, sustainability is an increasingly important factor. It is important to make sure that the server racks in data centers are sufficiently cooled whereas too much forced cooling leads to economical losses and a waste of energy...
متن کاملAn Improved Modular Modeling for Analysis of Closed-Cycle Absorption Cooling Systems
A detailed modular modeling of an absorbent cooling system is presented in this paper. The model including the key components is described in terms of design parameters, inputs, control variables, and outputs. The model is used to simulate the operating conditions for estimating the behavior of individual components and system performance, and to conduct a sensitivity analysis based on the give...
متن کاملThe Study of Thermostat Impact on Energy Consumption in a Residential Building by Using TRNSYS
The present study investigates the effectiveness of thermostat control strategy in cooling energy consumption in residential buildings. To evaluate the energy consumption, two scenarios including a residential zone with and without the thermostat control system are assumed. The TRNSYS software provides an efficient numerical tool to model and evaluate a cooling system. Furthermore, since solar-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011