Experimental and numerical analyses of the steady flow field around an aortic Björk-Shiley standard valve prosthesis.

نویسندگان

  • M Lei
  • A A van Steenhoven
  • D H van Campen
چکیده

To develop a numerical method for the description of the flow field around a Björk-Shiley (BS) standard valve prosthesis in aortic position, detailed experimental measurements and numerical calculations are performed under steady flow conditions. The experiment was conducted at Reynolds numbers up to 800. In order to perform LDA measurement of velocity in the vicinity of the valve with a curved sinus boundary, a mixture of oil and kerosine was used as the fluid which exactly matches the refractive index of the perspex aortic model. The velocity profiles at six positions in the vicinity and downstream of the valve were measured, including both axial and radial velocity components. The results show very clearly the existence of two nearly symmetric spiral vortex streams downstream of the valve. There is no recirculation area in the aorta downstream and also no obvious stagnation area in the minor orifice region near the valve when Re less than or equal to 800. Theoretically, the flow field of a BS valve is simulated by the flow pattern around a circular plate with an angle of incidence to the approaching stream. The numerical calculations were carried out by means of a 2-D model using the FEM together with the penalty function method. The maximum Reynolds number is 700. The results agree with the experimental results in the plane of symmetry when the Reynolds number is small. However, as the Reynolds number increases, the difference becomes evident. Our conclusion is that the steady flow field of a BS valve is completely 3-dimensional, featured by two spiral vortices. It cannot be simulated exactly by 2-D numerical calculations. To get more detailed and complete information about the flow field of this valve, 3-D numerical calculations are needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic valve replacement in patients over 70 years.

Twenty-seven patients 70 years of age or more were operated upon with aortic valvular replacement with an early mortality rate of 7%. No more patients died during a mean follow-up period of 28 months. The Björk-Shiley standard tilting disc valve was implanted in 15 cases and the new convexo-concave model in 12 cases. Sixty-seven per cent of the patients had narrow aortic roots (21 and 23 mm pro...

متن کامل

Aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis. Clinical experiences in 50 cases.

Single aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis has been performed in 50 patients since April 1971. None of the total of six deaths (12.0%) was attributable to malfunction of the prosthesis or to embolic complications. Follow-up examination showed insignificant or moderate prosthetic regurgitation in two patients and moderate paravalvular leakage in one patie...

متن کامل

Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.

Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley p...

متن کامل

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

Streptokinase treatment of a thrombosed Björk-Shiley prosthesis in the aortic position.

Dysfunction of a mechanical prosthetic valve caused by thrombus formation is usually treated surgically. A patient with a thrombosed Björk-Shiley valve in the aortic position was treated successfully with intravenous streptokinase. The considerable improvement in the patient's clinical condition and the phonocardiographic, echocardiographic, and cinefluoroscopic evidence of normalisation of pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 1992