An efficient 4D processing flow for variable-depth streamer data
ثبت نشده
چکیده
Variable-depth streamer acquisition is now widely used, achieving a bandwidth of more than 6 octaves (2.5 to 200 Hz) and excellent lateral resolution and providing improved impedance and reservoir analysis. This acquisition and processing method is based on towing the streamer deep, using a variable-depth profile optimized to ensure receiver notch diversity at the imaging stage and a deghosting method that takes advantage of the notch diversity. For 4D processing of monitors now acquired with variable-depth cables and with a baseline consisting of a flat towed streamer, we must deal with two processing issues. First, raypaths of traces acquired at the same surface locations differ; second, receiver ghosts lead to different wavelets. A 4D coprocessing flow is introduced that codatums 4D vintages to a common datum early in the sequence. Furthermore, a new deghosting technique is applied to variable-depth and conventional data. This processing flow gives excellent repeatability with 4D noise of less than 10% on a zero-time repeatability test with North Sea data from 2013.
منابع مشابه
3D and 4D Seismic Data Integration in Static and Dynamic Reservoir Modeling: A Review
Reservoir modeling is the process of generating numerical representations of reservoir conditions and properties on the basis of geological, geophysical, and engineering data measured on the Earth’s surface or in depth at a limited number of borehole locations. Therefore, reservoir modeling requires an incorporation of the data from a variety of sources, along with an integration of knowledge a...
متن کاملVisualization of Concrete Slump Flow Using the Kinect Sensor
Workability is regarded as one of the important parameters of high-performance concrete and monitoring it is essential in concrete quality management at construction sites. The conventional workability test methods are basically based on length and time measured by a ruler and a stopwatch and, as such, inevitably involves human error. In this paper, we propose a 4D slump test method based on di...
متن کاملAccelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction
Introduction 2D phase contrast (PC) CMR is currently the standard clinical imaging sequence for evaluation of blood flow [1]. Recently, 3D time-resolved PC CMR (4D-PC) has been used for quantification and visualization of blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times (often 10-20 minutes), which reduces its clinical feasibility and leads ...
متن کامل4D Model Flow: Precomputed Appearance Alignment for Real-time 4D Video Interpolation
We introduce the concept of 4D model flow for the precomputed alignment of dynamic surface appearance across 4D video sequences of different motions reconstructed from multi-view video. Precomputed 4D model flow allows the efficient parametrization of surface appearance from the captured videos, which enables efficient real-time rendering of interpolated 4D video sequences whilst accurately rep...
متن کاملColour Constrained 4D Flow
The addition of colour information to the computation of range/scene flow is proposed to improve its accuracy and robustness to ambiguities. This is applied in the form of additional optical flow constraints from aligned colour image data. Combining constraints gives improved velocity displacement fields for both synthetic and real datasets over using depth alone, or in using depth plus intensi...
متن کامل