■ Abstract The Jefferson Laboratory’s superconducting radiofrequency (srf ) Continuous Electron Beam Accelerator Facility (CEBAF) provides multi-GeV continuouswave (cw) beams for experiments at the nuclear and particle physics interface. CEBAF comprises two antiparallel linacs linked by nine recirculation beam lines for up to five passes. By the early 1990s, accelerator installation was proceeding in parallel with commissioning. By the mid-1990s, CEBAF was providing simultaneous beams at different but correlated energies up to 4 GeV to three experimental halls. By 2000, with srf development having raised the average cavity gradient to 7.5 MV/m, energies up to nearly 6 GeV were routine, at 1–150 μA for two halls and 1–100 nA for the other. Also routine are beams of >75% polarization. Physics results have led to new questions about the quark structure of nuclei, and therefore to user demand for a planned 12 GeV upgrade. CEBAF’s enabling srf technology is also being applied in other projects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Feedback System for Energy and Beam Stabilization

The electron beams being delivered to targets of the Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Accelerator Facility (Jefferson Lab) are plagued with undesirable positional and energy fluctuations. These fluctuations primarily occur at harmonics of the power line frequency (60, 120, 180, etc. hertz), and their cause is rooted in electromagnetic fields gen...

متن کامل

Review of Alignment Activities at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (Jefferson Lab) comprises a 6 GeV continuous electron beam accelerator (CEBAF) delivering beam to three experimental halls, and a kilowatt range tunable free electron laser (FEL), currently being upgraded to a 10 kW machine. The progression into steady state experimental runs at the facility has allowed the alignment group the opportunity to in...

متن کامل

Jefferson Lab, a Status Report

Thomas Jefferson National Accelerator Facility (Jefferson Lab; formerly known as CEBAF), operates a 4 GeV, 200 PA continuous wave (CW) electron accelerator that re-circulates the beam five times through two superconducting 400 MeV linacs. Electrons can be extracted from any of the five recirculation passes and beam can be simultaneously delivered to the three experimental halls. As the commissi...

متن کامل

The Cebaf Beam Scraping Monitor*

The Beam Scraping Monitor (BSM) is used to detect small amounts of beam loss in Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF). The BSM acts as an early warning system that alerts CEBAF operators when the beam loss exceeds 10 to 20 nA. This allows the CEBAF operators to adjust the beam orbit before beam loss reaches the Beam Loss Accounting (BLA) system threshold (present...

متن کامل

Thomas Jefferson National Accelerator Facility JLAB-TN-01-029 UNIQUE ELECTRON POLARIMETER COMPARISON AND SPIN–BASED ENERGY MEASUREMENT

A careful intercomparison of the relative analyzing power of five electron beam polarimeters was performed with the CEBAF accelerator at Thomas Jefferson National Accelerator Facility (JLab) during a dedicated two day machine development period. This is the first time such a high precision comparison between polarimeters of the Mott, Compton, and Møller type has been made. A Wien–style spin man...

متن کامل