A screening procedure for primary aldosteronism based on the Diasorin Liaison automated chemiluminescent immunoassay for direct renin.

نویسندگان

  • C A Dorrian
  • B J Toole
  • S Alvarez-Madrazo
  • A Kelly
  • J M C Connell
  • A M Wallace
چکیده

BACKGROUND Primary aldosteronism (PA), the most common secondary cause of hypertension, can be screened for using the aldosterone/renin ratio. This ratio is raised in PA and its accuracy depends on the ability to measure plasma renin at extremely low concentrations. METHODS We compared two different procedures for assessing plasma renin. The conventional method, which measures plasma renin activity (PRA), is technically demanding and laborious, and the Diasorin Liaison method, which measures plasma renin concentration (PRC), is an automated immunoassay. Results from each method were used to calculate the aldosterone/renin ratio (ARR) and the performance of the Diasorin Liaison method compared with that of the conventional assay using receiver operator characteristic curves. RESULTS The analytical and functional sensitivity of the PRC method were 2.1 and 5 microIU/mL, respectively. Intra- and inter-assay precision were <7.2% and 10.4%, respectively. There was significant (9%) prorenin interference. Samples with PRA > 1.0 ng/mL/h showed significant correlation with PRC (r = 0.93; P < 0.05; n = 146); however, with PRA < 1.0 ng/mL/h, no significant correlation occurred (r = 0.14; P < 0.05; n = 79). An aldosterone (pmol/L)/PRC(microIU/mL) ratio of >35, in patients with aldosterone >300 pmol/L, resulted in 100% sensitivity and 93% specificity, when compared with the commonly accepted aldosterone (pmol/L)/PRA (ng/mL/h) ratio of >750, in identifying patients who may suffer from PA. CONCLUSION This study indicates the feasibility of using the automated PRC assay as a replacement for the conventional manual PRA assay in calculating the ARR as a first-line screen for PA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory Experience with the Liaison Analyzer in the Diagnosis of Clostridium Difficile-Associated Diarrhea

BACKGROUND Chemiluminescent or enzyme-linked fluorescent immunoassays are commonly used to diagnose Clostridium difficile-associated diarrhea. METHODS The LIAISON analyzer (DiaSorin, Italy) was compared to miniVIDAS (bioMérieux, France) and, furthermore, to culture of toxigenic strains. In total, 249 native stool samples were analyzed. Sensitivities, specificities, and positive and negative p...

متن کامل

Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

BACKGROUND The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. METHODS We studied 228 osteoporo...

متن کامل

Telling Tails

The diagnosis of curable, secondary causes of hypertension is a satisfying but challenging aspect, for both patient and doctor, of the clinical management of hypertension. They are probably under-recognized, and the enthusiasm to look for causes is blunted by low pickup rates in unselected patients. Young age encourages a search more because the alternative is many decades of drug treatment tha...

متن کامل

Evaluation of LIAISON Treponema Screen, a novel recombinant antigen-based chemiluminescence immunoassay for laboratory diagnosis of syphilis.

The purpose of this study was to evaluate the diagnostic performance of LIAISON Treponema Screen (DiaSorin, Saluggia, Italy), a new automated chemiluminescence immunoassay (CLIA), in comparison with that of rapid plasma reagin (RPR) and the following currently used treponemal tests: hemagglutination test (TPHA), immunoenzymatic assay (EIA), and Western blot (WB). First, a retrospective study wa...

متن کامل

Evaluation of the LIAISON chemiluminescence immunoassay for diagnosis of syphilis.

We report the results of an evaluation of the LIAISON Treponema pallidum-specific assay, a one-step sandwich chemiluminescence immunoassay (CLIA), as a screening test and as a confirmatory test for the diagnosis of syphilis. The assay was compared with the CAPTIA Syphilis-G enzyme immunoassay (EIA) and with a testing algorithm that also included the rapid plasma reagin (RPR) and T. pallidum par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of clinical biochemistry

دوره 47 Pt 3  شماره 

صفحات  -

تاریخ انتشار 2010