High Intensity Focused Ultrasound Therapy Combined with 3d Real Time Tracking Motion System

نویسندگان

  • M. Pernot
  • M. Tanter
چکیده

For optimal treatment conditions, patient motion, particularly respiratory motion, must be monitored and corrected during HIFU treatments. We propose here a new generation of multi-channel HIFU systems able to track and correct in real-time the 3D motion of tissues. It is based on an accurate ultrasonic speckle tracking method for both following and compensating the motion of the tumor. The displacement estimation is based on 1D cross-correlation of the RF signals at two different times. The complete 3D motion estimation requires using at least three sub-apertures on a large phased array. The motion tracking sequences are interleaved with HIFU sequences at a high repetition rate. This provides a feedback for the HIFU beam steering correction and HIFU experiments combined with 3D real-time motion correction are successfully performed in moving fresh tissues samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-D real-time motion correction in high-intensity focused ultrasound therapy.

A method for tracking the 3-D motion of tissues in real-time is combined with a 2-D high-intensity focused ultrasound (US), or HIFU, multichannel system to correct for respiratory motion during HIFU therapy. Motion estimation is based on an accurate ultrasonic speckle-tracking method. A pulse-echo sequence is performed for a subset of the transducers of the phased array. For each of these subap...

متن کامل

Three dimensional motion compensation for real-time MRI guided focused ultrasound treatment of abdominal organs

Purpose/Introduction MR-guided High Intensity Focused Ultrasound (HIFU) for the ablation of tumors in abdominal organs under freebreathing conditions poses two challenges: 1) The current organ position in 3D-space must be continuously tracked in order to reposition the focal point of the HIFU-device to avoid undesired tissue damage. 2) Phase variations due to the organ displacement must be corr...

متن کامل

A Reliable Real Time Liver Motion Tracking for Application in Magnetic Resonance guided High Intensity Focused Ultrasound Therapy

Introduction High-intensity focused ultrasound has shown potential for ablating liver tumors without the need for surgical procedures [1]. However, the long duration of HIFU scans (~2hrs) and the varying respiratory motion requires that features identified for sonication be tracked in real time during the procedure [2]. The real time tracking would enable a free-breathing MRgFUS treatment and t...

متن کامل

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003