Occupant Interactions and Effectiveness of Natural Ventilation Strategies in Contemporary New Housing in Scotland, UK

نویسندگان

  • Tim Sharpe
  • Paul Farren
  • Stirling Howieson
  • Paul Tuohy
  • Jonathan McQuillan
  • Gary Adamkiewicz
  • M. Patricia Fabian
چکیده

The need to reduce carbon emissions and fuel poverty has led to increased building envelope air tightness, intended to reduce uncontrolled ventilation heat losses. Ventilation strategies in dwellings still allow the use of trickle ventilators in window frames for background ventilation. The extent to which this results in "healthy" Indoor Air Quality (IAQ) in recently constructed dwellings was a concern of regulators in Scotland. This paper describes research to explore this. First a review of literature was conducted, then data on occupant interactions with ventilation provisions (windows, doors, trickle vents) gathered through an interview-based survey of 200 recently constructed dwellings, and measurements made on a sample of 40 of these. The main measured parameter discussed here is CO2 concentration. It was concluded after the literature review that 1000 ppm absolute was a reasonable threshold to use for "adequate" ventilation. The occupant survey found that there was very little occupant interaction with the trickle ventilators e.g., in bedrooms 63% were always closed, 28% always open, and in only 9% of cases occupants intervened to make occasional adjustments. In the measured dwellings average bedroom CO2 levels of 1520 ppm during occupied (night time) hours were observed. Where windows were open the average bedroom CO2 levels were 972 ppm. With windows closed, the combination of "trickle ventilators open plus doors open" gave an average of 1021 ppm. "Trickle ventilators open" gave an average of 1571 ppm. All other combinations gave averages of 1550 to 2000 ppm. Ventilation rates and air change rates were estimated from measured CO2 levels, for all dwellings calculated ventilation rate was less than 8 L/s/p, in 42% of cases calculated air change rate was less than 0.5 ach. It was concluded that trickle ventilation as installed and used is ineffective in meeting desired ventilation rates, evidenced by high CO2 levels reported across the sampled dwellings. Potential implications of the results are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Post-Pandemic Housing Architecture: Lessons from Covid19

Like other crises, the coronavirus epidemic has had a significant impact on our lives. As a result, the built environment has changed in order to adapt to new conditions and needs. Since Covid19 will not be the first and possibly the last epidemic, housing design must also adapt to the new reality. At present, the spatial properties of housing are influenced by strategies of social distance, qu...

متن کامل

Case study investigation of indoor air quality in mechanically ventilated and naturally ventilated UK social housing

There is a significant lack of indoor air quality research in low energy homes. This study compared the indoor air quality of eight newly built case study homes constructed to similar levels of air-tightness and insulation; with two different ventilation strategies (four homes with Mechanical Ventilation with Heat Recovery (MVHR) systems/Code level 4 and four homes naturally ventilated/Code lev...

متن کامل

Evaluation of Health Housing Characteristics in Kashan; Case study: Air Health

Today, the issue of providing health through environmental regulation has become an urgent need. The main issue of this research is to find the indicators and pattern of the type of housing that provides health through air, ventilation and respiration based on traditional medicine. The research is further aimed at studying successful examples of traditional and contemporary housing in Kashan to...

متن کامل

'The Cup of Kindness’? Dominant Social Norms and Muslims’ Social Integration in Scotland

Since the 9/11 bombings in New York, and the 7/7 bombings in London,Muslims’ integration in the UK has been under intense scrutiny. Muslimintegration, however, has long been a matter of debate in Britain, revolvingaround the maintenance of Muslims’ distinctive identity and practice. Forinstance, David Cameron (Cameron, 2011), Britain’s then Prime Minister,announced...

متن کامل

“Horses for Courses”; Comment on “Translating Evidence Into Healthcare Policy and Practice: Single Versus Multi-Faceted Implementation Strategies – Is There a Simple Answer to a Complex Question?”

This commentary considers the vexed question of whether or not we should be spending time and resources on using multifaceted interventions to undertake implementation of evidence in healthcare. A review of systematic reviews has suggested that simple interventions may be just as effective as those taking a multifaceted approach. Taking cognisance of the Promoting Action on Research Implementat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015