Evaluation of the heart rate and arrhythmias following the maze procedure for chronic atrial fibrillation.
نویسندگان
چکیده
PURPOSE To assess the presence and the prevalence of arrhythmias and the variability of the heart rate in the medium-term postoperative period following the maze procedure for chronic atrial fibrillation (AF). METHODS Seventeen patients with a mean age of 51.7 +/- 12.9 years, who previously underwent the maze procedure without cryoablation for chronic atrial fibrillation, were evaluated with the 24 hour electrocardiogram (ECG)--Holter monitoring from the 6th month after the operation. Valvular and coronary procedures were concomitantly performed. RESULTS The mean heart rate during Holter monitoring was 82 +/- 8 bpm; the maximal heart rate was 126 +/- 23 bpm and the minimal heart rate 57 +/- 7 bpm. Sinus rhythm was found in 10 (59%) patients and atrial rhythm was found in 7 (41%). Supraventricular extrasystoles had a rate of 2.3 +/- 5.5% of the total number of heartbeats and occurred in 16 (94%) patients. Six (35%) patients showed nonsustained atrial tachycardia. Ventricular extrasystoles, with a rate of 0.8 +/- 0.5% of the total heartbeats, occurred in 14 (82%) patients. The chronotropic competence was normal in 9 (53%) patients and attenuated in 8 (47%). The atrioventricular conduction (AV) was unchanged in 13 (76%) patients and there were 4 (24%) cases of first degree atrioventricular block (AVB). CONCLUSION After the maze procedure, the values for the mean heart rate, AV conduction and chronotropic competence approach the normal range, although some cases show attenuation of the chronotropic response, first degree AV block or benign arrhythmias.
منابع مشابه
Letter to the Editor: "Evaluate the effects of curcumin on the prevention of atrial and ventricular arrhythmias and heart failure in patients with unstable angina"
Dear editor In a recent issue of the journal, Dastani et al. (2019) evaluate the effects of curcumin on the prevention of atrial and ventricular arrhythmias and heart failure in patients with unstable angina. Despite the fact that the topic was interesting, there were some defects and we wish to call to your attention important factual issues in this publication. The most cr...
متن کاملAssessment of P-wave indices as atrial fibrillation predictors in psoriasis patients
Background: Psoriasis is a prevalent chronic T cell mediated inflammatory skin disorder. Recent studies have reported an increase in the incidence of arrhythmia in psoriasis patients who run an excessive risk of metabolic syndrome and cardiovascular diseases. P-wave dispersion (PWD) and duration are important electrocardiographic (ECG) markers employed to anticipate the risk of atrial arrhythmi...
متن کاملElectrocardiographic nature of restored sinus rhythm after Cox maze procedure in patients with chronic atrial fibrillation who also had other cardiac surgery.
OBJECTIVE To characterise heart rate variability and high frequency components of restored sinus rhythm after the maze procedure. The maze procedure for chronic atrial fibrillation may prevent thrombotic events and improve the quality of life. However, the electrocardiographic nature of restored sinus rhythm after the maze procedure has not been fully elucidated. PATIENTS AND METHODS Between ...
متن کاملEffect of Alcohol on Heart: Case Presentation of Two Alcoholic Patients with Alcoholic Cardiomyopathy
Background: Alcohol consumption has multiple side effects on heart which can be divided to six subgroups: Heavy alcohol drinkers (80 g/day alcohol consumption) are most susceptible to cardiac complications. The aim of this study was to review alcohol side effects on heart and two present two alcoholic patients with alcoholic cardiomyopathy. Case report: Case A: A 52 year-old man presented with ...
متن کاملSurgical Outcomes of Cox-maze IV Procedure Using Bipolar Irrigated Radiofrequency Ablation and Cryothermy in Valvular Heart Disease
BACKGROUND We evaluated the efficacy of Cox-maze IV procedure using bipolar irrigated radiofrequency ablation and cryothermy in chronic atrial fibrillation associated with valvular heart disease. MATERIAL AND METHODS From November 2005 to June 2009, ninety four patients have undergone valvular heart surgery with Cox-maze IV procedure. Preoperative duration of atrial fibrillation was 7.6±6.5 y...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 72 5 شماره
صفحات -
تاریخ انتشار 1999