Should bioprostheses be considered the valve of choice for dialysis-dependent patients?

نویسندگان

  • Qiu Zhibing
  • Chen Xin
  • Xu Ming
  • Liu Lele
  • Jiang YingShuo
  • Wang LiMing
چکیده

BACKGROUND There is controversy regarding the choice of prosthetic valves in patients with cardiac valve disease and dialysis-dependent patients. This review assesses a 12-year experience and outcomes after valve replacement in patients on chronic preoperative renal dialysis, comparing survival and valve-related outcomes following valve replacement with bioprostheses versus mechanical prostheses in this population in china. METHODS From January 1999 and October 2011, 73 consecutive dialysis patients underwent cardiac valve replacement. The patients were divided into two groups: (Group B) bioprosthesis valves were implanted in 38 (52.1%) patients and (Group M) mechanical valves were implanted in 35 (47.9%) patients. Outcome measures included perioperative data, hospital mortality, major postoperative complications, follow-up outcomes, valve related morbidity and late survival. RESULTS There were no significant differences in terms of patient characteristics in the 2 groups. Thirty-three were isolated aortic valve replacements (45.2%); 28 were isolated mitral valve replacements (38.4%); 10 were combined aortic and mitral replacements (13.7%); 2 were combined tricuspid and mitral replacements (2.7%). The overall hospital mortality was 5.5% (n = 4) and was not different between Group B (5.3%) and Group M (5.7%). Low ejection fraction was the only independent predictors of hospital mortality. There was no significant difference between the groups in the overall rate of complications. The overall mean follow-up was 47 ± 23 months. According to the Kaplan-Meier analysis, late mortality, perivalvular leak and freedom from reoperation were similar in patients with mechanical and bioprosthesis valves. The bioprosthesis valve group had significantly higher freedom from thromboembelism-bleeding events (100% versus 77.6 ± 11.0%, p = 0.012), and valve-related morbidity (73.2 ± 10.1% versus 58.1 ± 10.9%, p = 0.035) in 5 years. Kaplan-Meier survival estimates at 1, 3, and 5 years were 0.971, 0.832, and 0.530 in group B, and 0.967, 0.848, and 0.568 in group M. CONCLUSIONS There is no significant difference in the perioperative morbidity and mortality, late survival of dialysis patients after cardiac valve replacement with bioprostheses versus mechanical valves. In spite of the limited sample size analyzed, its outcome and consistency to several previous reports supports a conclusion that bioprostheses rather than mechanical ones could be a favorable choice for valve replacement needs of renal failure patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prosthesis type has minimal impact on survival after valve surgery in patients with moderate to end-stage renal failure.

BACKGROUND Few previous studies have reported on the outcome of patients with renal failure (RF) undergoing valvular surgery, particularly with regard to choice of valve prosthesis. METHODS We retrospectively analyzed prospectively collected data from 155 patients with RF (mean age 62 +/- 14, 42% female) who underwent left-sided valve surgery from January 1998 to December 2006. Patients were ...

متن کامل

Relationship between resilience with illness behavior in dialysis patients

Dialysis patients are classified as special cases.These patients have to face various physiological changes and lots of psychological stress. This research aimed to study the relationship between resilience with illness behavior in dialysis patients. The study population consisted of all dialysis patients who have referred to the diemoalysis unit (78 participants); all of them have taken census...

متن کامل

Performance Evaluation of Magnetorheological Damper Valve Configurations Using Finite Element Method

The main purpose of this paper is to study various configurations of a magnetorheological (MR) damper valve and to evaluate their performance indices typically dynamic range, valve ratio, inductive time constant and pressure drop. It is known that these performance indices (PI) of the damper depend upon the magnetic circuit design of the valve. Hence, nine valve configurations are considered fo...

متن کامل

Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve: comparison of stentless versus stented bioprostheses.

OBJECTIVES The objective of this study was to compare stentless bioprostheses with stented bioprostheses with regard to their hemodynamic behavior during exercise. BACKGROUND Stentless aortic bioprostheses have better hemodynamic performances at rest than stented bioprostheses, but very few comparisons were performed during exercise. METHODS Thirty-eight patients with normally functioning s...

متن کامل

Mechanical prosthesis is reasonable for mitral valve replacement in patients approximately 65 years of age.

BACKGROUND The long-term results of mitral valve replacement (MVR; n = 631) with a bileaflet mechanical prosthesis or a Carpentier-Edwards Perimount bioprosthesis were evaluated in Japanese patients of different age groups. METHODS A total of 507 bileaflet mechanical prostheses and 124 bioprostheses have been implanted since 1982 at our institution. Follow-up was completed for 6,598 patient-y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013