The impact of temperature on the performance of anaerobic biological treatment of perchlorate in drinking water.
نویسندگان
چکیده
A 20-month pilot-scale study was conducted to examine the impact of temperature on the performance of an anaerobic biological contractor used to treat perchlorate-contaminated water. The contractor was successfully acclimated with indigenous microorganisms. Influent temperatures varied from 1.4 to 30 degrees C. The objectives of the study were to investigate the effects of temperature on perchlorate removal, nitrate removal, nitrite formation, dissolved oxygen consumption, sulfide production, and nutrient acetate consumption. The results confirmed that consistent biological perchlorate removal to 2 microg /L is feasible at temperatures above 10 degrees C. Effluent concentrations of perchlorate, nitrate, and dissolved oxygen varied inversely with temperature, while sulfide varied positively with temperature. Under the conditions that prevailed during this study, 10 degrees C was a threshold temperature below which microbial activity, including perchlorate reduction, decreased dramatically.
منابع مشابه
Microbial Degradation of Perchlorate: Principles and Applications
Perchlorate (ClO4) release into the environment has occurred primarily in association with its manufacture and use in solid rocket propellant. When released into groundwater, perchlorate can spread over large distances because it is highly soluble in water and adsorbs poorly to soil. Two proven techniques to remove perchlorate from drinking water are anaerobic biological reactors and ion exchan...
متن کاملتعیین غلظت پرکلرات در آب و خاک سطحی مناطق جنگی (مطالعه موردی: شهرستان خرمشهر)
Background and Objectives: Perchlorate, as an emerging contaminant, has attracted notice of the most individuals and organizations. Presence of perchlorate in the human body can lead to inappropriate regulation of metabolism in adults. Moreover, due to inhibition of iodide uptake in the thyroid gland, it causes neurological and behavioral problems in infants and children. United States Environm...
متن کاملPerformance Evaluation of Point-Of-Use Drinking Water Treatment Units in Removal of Heavy Metals and Dissolved Solids from Drinking Water Supply in Tabriz
Introduction: Application of point-of-use (POU) drinking water treatment units is expanding across the world due to the increased concerns about the adverse health effects of water pollution. The main treatment systems of these devices are mostly activated carbon and nano-filter or reverse osmosis. Materials and Methods: This study was conducted to evaluate the effect of using POU units on phy...
متن کاملImpact of Climate Change on Organic Carbon Removal Efficiency in Jajrood Catchment: From Dam to Water Treatment Plant
Background and purpose: Jajrood River is one of the major drinking water supply rivers in Tehran, so, the effects of climate change on its quantitative and qualitative resources are highly important. This study aimed at investigating the effect of climate change on organic carbon removal in Jajrood basin. Materials and methods: In this descriptive cross-sectional study, CanESM2 general circula...
متن کاملCadmium contamination of drinking water and its treatment using biological chelators
Background: Cadmium (Cd) is an extremely toxic metal and environmental exposure to Cd has been particularly problematic in the world. Oral exposure to Cd may result in adverse effects on a number of tissues, the immune system, and the cardiovascular system. Compounds containing Cd are also carcinogenic. The presence of Cd in drinking water resources in the southeastern region of Rafsanjan plain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water research
دوره 43 7 شماره
صفحات -
تاریخ انتشار 2009