Detection of in utero marijuana exposure by GC-MS, ultra-sensitive ELISA and LC-TOF-MS using umbilical cord tissue.
نویسندگان
چکیده
Smoking marijuana during pregnancy can cause health problems in the neonate. The detection of exposure can guide treatment to meet the short- and long-term medical and social needs. Umbilical cord tissue was analyzed for 11-nor-delta-9-carboxy-tetrahydrocannabinol (THC-COOH) by gas chromatography-mass spectrometry (GC-MS), and compared with ultra-sensitive enzyme-linked immunosorbent assay (ELISA) and liquid chromatography time-of-flight mass spectrometry (LC-TOF-MS). Fortified extracts of drug-free cord tissue were used to determine the sensitivity and specificity of the LC-TOF-MS and ELISA assays, and 16 de-identified patient specimens previously analyzed by GC-MS were tested for THC-COOH by both methods. The cutoffs were 0.050 ng/g for the GC-MS assay, 0.1 ng/g for the ELISA assay and 1 ng/g for the LC-TOF-MS assay. Twelve specimens were negative by all three methods. Seven specimens were positive by GC-MS with concentrations from 0.066 to 6.095 ng/g. ELISA and LC-TOF-MS did not detect one specimen that was positive by GC-MS. LC-TOF-MS missed one specimen that was detected by GC-MS and ELISA. Five positive specimens were detected by all three methods. These results were consistent with the cutoff for each method. No false positives were detected by LC-TOF-MS or ELISA. Umbilical cord tissue is a viable specimen for the detection of in utero marijuana exposure. ELISA and GC-MS were more sensitive than LC-TOF-MS for the detection of THC-COOH in cord tissue, with the GC-MS method providing superior sensitivity.
منابع مشابه
Detection of neonatal drug exposure using umbilical cord tissue and liquid chromatography time-of-flight mass spectrometry.
BACKGROUND A method for qualitative detection of 57 drugs and metabolites in umbilical cord tissue using liquid chromatography time-of-flight (TOF) mass spectrometry is described. METHODS Results from 32 deidentified positive specimens analyzed by an outside laboratory using "screen with reflex to confirmation" testing were compared with TOF results. In addition, 57 umbilical cord tissue spec...
متن کاملEnhanced Isotopic Ratio Outlier Analysis (IROA) Peak Detection and Identification with Ultra-High Resolution GC-Orbitrap/MS: Potential Application for Investigation of Model Organism Metabolomes
Identifying non-annotated peaks may have a significant impact on the understanding of biological systems. In silico methodologies have focused on ESI LC/MS/MS for identifying non-annotated MS peaks. In this study, we employed in silico methodology to develop an Isotopic Ratio Outlier Analysis (IROA) workflow using enhanced mass spectrometric data acquired with the ultra-high resolution GC-Orbit...
متن کاملEnhanced Metabolite Profi ling from Bark of Alangium Salviifolium Using LC/MS and GC/Q-TOF Techniques
Traditional herbal remedies are used as alternative medicines for a number of diseases. Alangium salviifolium is one such plant, used as traditional medicinal plant. Several investigations have been performed using this plant extract to demonstrate its therapeutic value. However, very few attempts have been made to identify the extensive metabolite composition of this plant. In this Application...
متن کاملQuantitative analysis of lipids: a higher-throughput LC–MS/MS-based method and its comparison to ELISA
AIM Lipids such as prostaglandins, leukotrienes and thromboxanes are released as a result of an inflammatory episode in pain (central and peripheral). METHODOLOGY & RESULTS To measure these lipids as potential mechanistic biomarkers in neuropathic pain models, we developed a higher-throughput LC-MS/MS-based method with simultaneous detection of PGE2, PGD2, PGF2α, LTB4, TXB2 and 2-arachidonoyl...
متن کاملMethod validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.
Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of analytical toxicology
دوره 37 7 شماره
صفحات -
تاریخ انتشار 2013