Cortical evoked response audiometry thresholds and neuroleptic, sedative, hypnotic drugs.

نویسندگان

  • P H Dejonckere
  • J Lebacq
  • C Coryn
چکیده

Cortical evoked response audiometry is adequate for approximating hearing threshold levels with frequency specificity when the psychoacoustic responses lack reliability and reproducibility (compensation claim). It is well-known that control of wakefulness is essential for the reliability of slow vertex responses (SVR). Therefore, sedative, hypnotic, and neuroleptic drugs are supposed to have possible adverse effects on the detection of SVR. In contrast, brainstem evoked responses (BER) have proved not to be significantly affected by therapeutic doses of these compounds. The purpose of our study was to assess the reliability of SVR-threshold definition in subjects taking neuroleptic, sedative, and hypnotic drugs. Fifteen subjects examined for occupational hearing loss at the Fund for Occupational Diseases in Brussels and regularly taking one or several of these drugs were compared with 27 comparable controls. In each subject the auditory thresholds were defined with both techniques: SVR (1, 2, and 3 kHz) and BER (clicks). A highly significant difference is observed between the two groups: In the group receiving drugs, the SVR threshold for 3 kHz is 12.1 dB (average) higher than the BER threshold, whereas in the group without drugs, the SVR threshold for 3 kHz is 7.77 dB (average) lower than the BER threshold. In the drug group, large interindividual differences are observed. It may be concluded that the use of neuroleptics, sedatives, and hypnotics renders the auditory threshold definition with SVR completely unreliable. In using SVR for medicolegal threshold definition, controlling the 3-kHz threshold with BER always is necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of hearing thresholds: comparison of cortical evoked response audiometry and auditory steady state response audiometry techniques.

The present study evaluated how well auditory steady state response (ASSR) and tone burst cortical evoked response audiometry (CERA) thresholds predict behavioral thresholds in the same participants. A total of 63 ears were evaluated. For ASSR testing, 100% amplitude modulated and 10% frequency modulated tone stimuli at a modulation frequency of 40Hz were used. Behavioral thresholds were closer...

متن کامل

بررسی دقت تخمین آستانه شنوایی بهنجار بوسیله پاسخ‌های برانگیخته قشر شنوایی

Background: Cortical Evoked Response Audiometry (CERA) refers to prediction of behavioral pure-tone thresholds (500-4000 Hz) obtained by recording the N1-P2 complex of auditory long latency responses. CERA is the preferred method for frequency–specific estimation of audiogram in conscious adults and older children. CERA has an increased accuracy of determination of the hearing thresholds of ale...

متن کامل

A comparison between middle latency responses and late auditory evoked potentials for approximating frequency-specific hearing levels in medicolegal patients with occupational hearing loss.

To evaluate the medicolegal relevance of middle latency responses for objectively approximating frequency-specific hearing levels in subjects with occupational hearing loss, we compared the middle latency response with the cortical response in 22 reliable subjects who had noise-induced hearing loss and were submitting claims for compensation and 21 subjects who had noise-induced hearing loss bu...

متن کامل

Separation of Sedative – Hypnotic Drugs with Mixed Micellar Liquid Chromatography

Separation of ten sedative- hypnotic drugs was performed by RP-HPLC using mixed micellar mobile phase. Effect of temperature, type and amount of organic modifier in mobile phase on efficiency (N) and asymmetry factor (B/A) showed that, the appropriate conditions for a good separation were 35°C and 7% (V/V) butanol in mobile phase.  Variations of selectivity factor versus butanol concent...

متن کامل

Malingering in Audiology

The application of slow vertex response audiometry (cortical evoked response audiometry), mainly in the diagnosis of pseudohypoacusis, is reported. This procedure is of interest in forensic audiology.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The international tinnitus journal

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2000